Bhakta Sourav, Raman Anand, Ajish Juby K
Radiation and Photochemistry Division, Bhabha Atomic Research Centre, Trombay, Mumbai, 400085, India.
Medical Division, Bhabha Atomic Research Centre, Trombay, Mumbai, 400085, India.
Appl Radiat Isot. 2024 Oct;212:111453. doi: 10.1016/j.apradiso.2024.111453. Epub 2024 Jul 22.
In this study we have synthesized polystyrene based plastic scintillators (PS) loaded with commercially available fluorophores like p-Terphenyl and 1,4-bis(5-phenyloxazol-2-yl) benzene (POPOP). Optimum concentration of the fluorophores in the synthesized PS was determined. The PS exhibited 1.55 ± 0.05 times better light output than UPS-923A, a commercial PS. Emission maxima were obtained at 423 nm with an energy linearity of 99.78% up to 1.061 MeV. Radiation damage of PS by Co-60 irradiation led to 22.3% loss of light yield at 50 kGy radiation dose which is better than the commercial one. The loss of light output in the PS due to radiation damage was because of the degradation of polystyrene matrix rather than the fluorophores.