Suppr超能文献

空气中氡活度浓度的计量实现

Metrological realization of the radon activity concentration in air.

作者信息

Beck Thomas R, Biel Martin

机构信息

Federal Office for Radiation Protection, Koepenicker Allee 120-130, 10318, Berlin, Germany.

Federal Office for Radiation Protection, Koepenicker Allee 120-130, 10318, Berlin, Germany.

出版信息

Appl Radiat Isot. 2024 Oct;212:111448. doi: 10.1016/j.apradiso.2024.111448. Epub 2024 Jul 16.

Abstract

In the framework of the EMPIR research project Metrology for Radon, a facility was devised that provides stable and traceable atmospheres for the realization of radon activity concentration at a high metrological level. The facility is used to calibrate and test devices for measuring radon in the air. It enables precise long-term exposures in the range between 100 Bq/m and 1000 Bq/m. The radon activity concentrations are realized with uncertainties of about 1.0 % (k = 1).

摘要

在欧洲计量研究计划(EMPIR)“氡计量学”研究项目的框架内,设计了一种装置,该装置可提供稳定且可溯源的环境,以在高计量水平上实现氡活度浓度。该装置用于校准和测试空气中氡测量设备。它能够在100 Bq/m³至1000 Bq/m³的范围内进行精确的长期暴露。所实现的氡活度浓度的不确定度约为1.0%(k = 1)。