Biomechanics and Engineering Team, Combat Capabilities Development Command Soldier Center, Natick, Massachusetts, USA.
Civil and Mechanical Engineering Department, United States Military Academy, West Point, New York, USA.
Eur J Sport Sci. 2024 Sep;24(9):1313-1318. doi: 10.1002/ejsc.12148. Epub 2024 Aug 1.
A novel fixation system for a hand-held dynamometer (HHD) was designed to enable isometric muscle measurements on various muscle groups of strong, healthy individuals in a field setting. The objective of this study was to evaluate the intra- and interrater reliability of the system and determine its suitability for use by multiple researchers within large-scale data collections during field activities. Four researchers tested eight healthy subjects, who each completed eight different maximal isometric muscle strength assessments using the HHD fixation system. Intraclass correlation coefficients (ICC) results were evaluated with a 95% confidence interval. ICC results for interrater reliability demonstrated excellent agreement of all eight measurements tested. ICC results for intrarater reliability demonstrated excellent agreement for six out of eight measurements. This system provides a new opportunity for several different high-quality maximal muscle strength measurements to be collected by multiple data collectors on large numbers of strong, healthy individuals in a field setting.
一种新型的手持测力计(HHD)固定系统被设计用于在现场环境中对强壮健康个体的各种肌肉群进行等长肌肉测量。本研究的目的是评估该系统的内部和外部可靠性,并确定其是否适合在现场活动中进行大规模数据收集时由多名研究人员使用。四名研究人员测试了八名健康受试者,每位受试者使用 HHD 固定系统完成八项不同的最大等长肌肉力量评估。采用 95%置信区间评估组内相关系数(ICC)结果。所有八项测试的 ICC 结果均显示出极好的一致性。内部可靠性的 ICC 结果显示,八项测试中有六项的一致性极好。该系统为在现场环境中对大量强壮健康个体进行多次高质量最大肌肉力量测量提供了新的机会,由多个数据收集器进行测量。