一种基于植酸的钴锰双金属有机气凝胶(PA-CoMn-1 :  : 2 - )作为用于非甾体抗炎药4-乙酰氨基酚电化学检测的修饰剂。

A phytic acid-based CoMn bimetallic metal-organic aerogel (PA-CoMn-1 :  : 2 - ) as a modifier for electrochemical detection of non-steroidal anti-inflammatory drug 4-acetaminophenol.

作者信息

Guo Huijun, Qi Yifei, Wang Guoxin, Zhang Yue, Li Siqi, Tan Boyu

机构信息

Center of Characterization and Analysis, Jinlin Institute of Chemical Technology Jilin 132000 China

出版信息

RSC Adv. 2024 Aug 6;14(34):24574-24584. doi: 10.1039/d4ra04012k. eCollection 2024 Aug 5.

Abstract

Metal phosphides and phosphate-based materials have received significant attention due to their high electrocatalytic activity, adjustable structure composition and stability. Herein, we introduce a phytic acid-based CoMn bimetallic metal-organic (PA-CoMn) aerogel as an electrode modifier, derived from PA and mixed transition metal ions (Co, Mn). We explored its performance in the sensitive sensing of non-steroidal anti-inflammatory drug 4-acetaminophenol (4-AP) for the first time. We investigated the electrochemical behavior of the modified screen-printed carbon electrode (SPCE) by cyclic voltammetry (CV) and differential pulse voltammetry (DPV). The PA-CoMn-1 : 1.5 : 0.5 aerogel/Nafion/SPCE proved to be highly sensitive and selective towards the detection of 4-AP. A double linear response was recorded for 4-AP over the range of 1 μM to 0.1 mM and lower detection limits (LOD) of 0.2133 μM. The applicability of the PA-CoMn-1 : 1.5 : 0.5 aerogel/Nafion/SPCE in the detection of 4-AP in commercial drug samples with good recoveries was investigated, confirming the great potential of PA-CoMn-1 : 1.5 : 0.5 aerogel/SPCE in clinical applications.

摘要

金属磷化物和磷酸盐基材料因其高电催化活性、可调节的结构组成和稳定性而受到广泛关注。在此,我们介绍一种基于植酸的钴锰双金属有机(PA-CoMn)气凝胶作为电极修饰剂,它由植酸和混合过渡金属离子(Co、Mn)衍生而来。我们首次探索了其在非甾体抗炎药4-乙酰氨基酚(4-AP)灵敏传感方面的性能。我们通过循环伏安法(CV)和差分脉冲伏安法(DPV)研究了修饰的丝网印刷碳电极(SPCE)的电化学行为。结果表明,PA-CoMn-1:1.5:0.5气凝胶/ Nafion / SPCE对4-AP的检测具有高灵敏度和选择性。在1 μM至0.1 mM范围内记录到4-AP的双线性响应,检测限(LOD)低至0.2133 μM。研究了PA-CoMn-1:1.5:0.5气凝胶/ Nafion / SPCE在商业药物样品中检测4-AP的适用性,回收率良好,证实了PA-CoMn-1:1.5:0.5气凝胶/ SPCE在临床应用中的巨大潜力。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/e2cc/11301407/ab684df9102b/d4ra04012k-s1.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验