Suppr超能文献

一种超灵敏的绿色同步因子分解荧光光谱法用于同时测定法维拉韦和莫那比拉韦:在药物、环境和生物基质中的应用。

An ultrasensitive green synchronous factorized spectrofluorimetric approach for the simultaneous determination of Favipiravir and Molnupiravir: Application to pharmaceutical, environmental, and biological matrices.

机构信息

Analytical Chemistry Department, Faculty of Pharmacy, Modern University for Technology and Information, Cairo, Egypt.

Analytical Chemistry Department, Faculty of Pharmacy, October 6 University, 6 October City, Giza, Egypt.

出版信息

Luminescence. 2024 Aug;39(8):e4837. doi: 10.1002/bio.4837.

Abstract

During the pandemic, Favipiravir (FVP) and Molnupiravir (MPV) have been widely used for COVID-19 treatment, leading to their presence in the environment. A green synchronous spectrofluorimetric method was developed to simultaneously detect them in environmental water, human plasma, and binary mixtures. Maximum fluorescence intensity was achieved at pH 8, with MPV exhibiting two peaks at 300 and 430 nm, and FVP showing one peak at 430 nm. A fluorescence subtraction method effectively removed interference, enabling direct determination of MPV at 300 nm and FVP at 430 nm. The method showed linearity within 2-13 ng/mL for FVP and 50-600 ng/mL for MPV, with recoveries of 100.35% and 100.12%, respectively. Limits of detection and quantification were 0.19 and 0.57 ng/mL for FVP and 10.52 and 31.88 ng/mL for MPV. Validation according to ICH and FDA guidelines yielded acceptable results. The method demonstrated good recoveries of FVP and MPV in pharmaceuticals, tap water and Nile water (99.62% ± 0.96% and 99.69% ± 0.64%) as per ICH guidelines and spiked human plasma (94.87% ± 2.111% and 94.79% ± 1.605%) following FDA guidelines, respectively. Its environmental friendliness was assessed using Green Analytical Procedure Index (GAPI) and the Analytical Greenness Metric (AGREE) tools.

摘要

在大流行期间,法匹拉韦(FVP)和莫努匹韦(MPV)已被广泛用于 COVID-19 的治疗,导致它们在环境中存在。开发了一种绿色同步荧光分光光度法,用于同时检测环境水中、人血浆中和二元混合物中的它们。在 pH 8 时达到最大荧光强度,MPV 在 300nm 和 430nm 处有两个峰,FVP 在 430nm 处有一个峰。荧光减法法有效地消除了干扰,能够直接在 300nm 处测定 MPV,在 430nm 处测定 FVP。该方法在 FVP 为 2-13ng/mL 和 MPV 为 50-600ng/mL 范围内呈线性,回收率分别为 100.35%和 100.12%。FVP 的检出限和定量限分别为 0.19 和 0.57ng/mL,MPV 的检出限和定量限分别为 10.52 和 31.88ng/mL。根据 ICH 和 FDA 指南进行的验证得到了可接受的结果。该方法在药品、自来水和尼罗河水中的 FVP 和 MPV 回收率良好(ICH 指南规定为 99.62%±0.96%和 99.69%±0.64%,FDA 指南规定为 94.87%±2.111%和 94.79%±1.605%)。使用绿色分析程序指数(GAPI)和分析绿色度指标(AGREE)工具评估了其环境友好性。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验