• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Recommendations for air quality standards for nitrogen dioxide and ozone.

作者信息

Lindvall T

出版信息

Scand J Work Environ Health. 1985;11 Suppl 3:3-9.

PMID:3911380
Abstract

The acute health effects of nitrogen dioxide and ozone critical to the general population are summarized. For long-term exposures to the former in the outdoor environment a six-month average limit value of 80 micrograms/m3 is recommended for the wintertime. When "new" residential areas are planned or when the limit value is used as an air quality standard for the nonindustrial indoor environment, the adequate six-months' average limit value for the winter would be 50 micrograms/m3. For short-term exposures to nitrogen dioxide outdoors a limit value of 320 micrograms/m3 (1-h average) is recommended, not to be exceeded more than 12 h per year, each time during a maximum of 2 h. This value should apply only to "old" residential areas in which nitrogen dioxide pollution cannot be reduced without large economical and practical consequences. The value 190 micrograms/m3 (1-h average), not to be exceeded more than 12 h per year, should apply to most residential areas, to recreational areas, and to all nonindustrial indoor environments. For short-term exposures to photochemical oxidants, as represented by ozone in nonindustrial outdoor environments, the acceptable short-term limit value should be 120 micrograms/m3 (1-h average), not to be exceeded more than 12 h per year. An additional 1-h outdoor ceiling value of 200 micrograms/m3 is recommended, not to be exceeded. For the nonindustrial indoor environment a 1-h ceiling value of 100 micrograms/m3 is recommended, not to be exceeded.

摘要

相似文献

1
Recommendations for air quality standards for nitrogen dioxide and ozone.
Scand J Work Environ Health. 1985;11 Suppl 3:3-9.
2
Health effects of nitrogen dioxide and oxidants.
Scand J Work Environ Health. 1985;11 Suppl 3:10-28.
3
Current asthma and respiratory symptoms among pupils in Shanghai, China: influence of building ventilation, nitrogen dioxide, ozone, and formaldehyde in classrooms.中国上海小学生当前的哮喘及呼吸道症状:教室建筑通风、二氧化氮、臭氧和甲醛的影响
Indoor Air. 2006 Dec;16(6):454-64. doi: 10.1111/j.1600-0668.2006.00439.x.
4
Health effects of air pollution. A review of clinical studies.
Clin Chest Med. 1992 Jun;13(2):201-14.
5
The association between childhood asthma prevalence and monitored air pollutants in metropolitan areas, United States, 2001-2004.美国大都市地区 2001-2004 年儿童哮喘患病率与监测空气污染物的关系。
Environ Res. 2010 Apr;110(3):294-301. doi: 10.1016/j.envres.2010.01.001. Epub 2010 Feb 1.
6
Personal exposure to nitrogen dioxide and its relation to indoor and outdoor air quality.
Tokai J Exp Clin Med. 1985 Aug;10(4):303-8.
7
Indoor air distribution of nitrogen dioxide and ozone in urban hospitals.城市医院中二氧化氮和臭氧的室内空气分布
Bull Environ Contam Toxicol. 2009 Aug;83(2):147-50. doi: 10.1007/s00128-009-9631-x. Epub 2009 Feb 6.
8
[Nitrogen dioxide and ozone exposures in a population sample from Ile-de-France].
Rev Epidemiol Sante Publique. 2000 Aug;48 Suppl 2:2S54-61.
9
Part 1. A time-series study of ambient air pollution and daily mortality in Shanghai, China.第一部分. 中国上海环境空气污染与每日死亡率的时间序列研究。
Res Rep Health Eff Inst. 2010 Nov(154):17-78.
10
Windsor, Ontario exposure assessment study: design and methods validation of personal, indoor, and outdoor air pollution monitoring.安大略省温莎暴露评估研究:个人、室内和室外空气污染监测的设计和方法验证。
J Air Waste Manag Assoc. 2011 Mar;61(3):324-38.