Suppr超能文献

不同眼轴长度白内障患者植入PanOptix三焦点人工晶状体后视觉质量改善情况分析

Analysis of visual quality improvement after implantation of PanOptix trifocal intraocular lens in cataract patients with different axial lengths.

作者信息

Yang Yin-Ping, Tan Ya, Liao Qiong

机构信息

Department of Cataract, Chongqing Eye and Vision Care Hospital·Aier Eye Hospital Group Chongqing 400000, China.

Department of Fundus Disease, Chongqing Eye and Vision Care Hospital·Aier Eye Hospital Group Chongqing 400000, China.

出版信息

Am J Transl Res. 2024 Jul 15;16(7):2995-3004. doi: 10.62347/FRJZ4885. eCollection 2024.

Abstract

OBJECTIVE

To assess the visual quality, both subjective and objective, of cataract patients with varying axial lengths (AL) after PanOptix trifocal intraocular lens (IOL) implantation and investigated the lens tilt and its correlation with visual outcomes.

METHODS

From July 2020 to June 2022, 70 patients (140 eyes) diagnosed with age-related cataracts and undergoing PanOptix implantation at Chongqing Eye and Vision Care Hospital, Aier Eye Hospital Group, were included. Patients were assigned to either the observation group (35 cases, 70 eyes with PanOptix trifocal IOL) or the control group (35 cases, 70 eyes with bifocal IOL). Patients were further subdivided based on AL into AL < 24 mm (observation group: 23 eyes; control group: 26 eyes) and AL ≥ 24 mm (observation group: 47 eyes; control group: 44 eyes). Postoperative follow-up lasted three months. Visual acuity (distant, intermediate, near), objective visual quality (Strehl ratio: SR, total eye modulation transfer function (MTF)), and visual aberrations were measured preoperatively and at 3 months post-operation.

RESULTS

Postoperatively, all groups saw significant improvements in uncorrected distance visual acuity (UCDVA), uncorrected intermediate visual acuity (UCIVA), and uncorrected near visual acuity (UCNVA) compared to preoperative values (T0) (all P < 0.05). Notably, UCIVA was significantly better in the observation group than in the control group (P < 0.05). At three months (T1), reductions in total high-order aberration (tHOA), internal high-order aberration (iHOA), coma, and trefoil aberrations were observed in both groups compared to baseline, with more significant decreases in the observation group (all P < 0.05). Both SR and MTF cutoff showed marked improvement from T0 to T1, with the observation group experiencing greater enhancements (both P < 0.05). The defocus curve of the observation group showed a gentle slope between +0.5 D and -3.0 D, maintaining superior visual acuity compared to the control group (P < 0.05). Subjective visual quality scores at T1 were significantly higher than at T0 for both groups (P < 0.05), with patients in the observation group scoring higher than those in the control group across all AL categories (P < 0.05). Spearman correlation analysis indicated that the tilt after PanOptix trifocal IOL implantation was associated with tHOA (r = 0.273, P = 0.022), iHOA (r = 0.433, P < 0.001), Trefoil (r = 0.360, P = 0.002) and coma (r = 0.688, P < 0.001).

CONCLUSION

PanOptix trifocal IOL implantation in cataract patients across different AL significantly enhances visual quality compared to bifocal IOLs, suggesting a strong case for its clinical adoption.

摘要

目的

评估不同眼轴长度(AL)的白内障患者在植入PanOptix三焦点人工晶状体(IOL)后的主观和客观视觉质量,并研究晶状体倾斜及其与视觉结果的相关性。

方法

2020年7月至2022年6月,纳入在爱尔眼科医院集团重庆眼视光医院诊断为年龄相关性白内障并接受PanOptix植入的70例患者(140只眼)。患者被分为观察组(35例,70只眼植入PanOptix三焦点IOL)和对照组(35例,70只眼植入双焦点IOL)。患者根据AL进一步细分为AL < 24 mm(观察组:23只眼;对照组:26只眼)和AL≥24 mm(观察组:47只眼;对照组:44只眼)。术后随访3个月。术前及术后3个月测量视力(远、中、近)、客观视觉质量(斯特列尔比:SR、全眼调制传递函数(MTF))和视觉像差。

结果

术后,与术前值(T0)相比,所有组的未矫正远视力(UCDVA)、未矫正中视力(UCIVA)和未矫正近视力(UCNVA)均有显著改善(均P < 0.05)。值得注意的是,观察组的UCIVA明显优于对照组(P < 0.05)。在3个月时(T1),与基线相比,两组的总高阶像差(tHOA)、内部高阶像差(iHOA)、彗差和三叶草像差均降低,观察组降低更显著(均P < 0.05)。从T0到T1,SR和MTF截止值均有显著改善,观察组改善更大(均P < 0.05)。观察组的散焦曲线在+0.5 D和 -3.0 D之间呈平缓斜率,与对照组相比保持了更好的视力(P < 0.05)。两组在T1时的主观视觉质量评分均显著高于T0时(P < 0.05),观察组在所有AL类别中的评分均高于对照组(P < 0.05)。Spearman相关性分析表明,PanOptix三焦点IOL植入后的倾斜与tHOA(r = 0.273,P = 0.022)、iHOA(r = 0.433,P < 0.001)、三叶草像差(r = 0.360,P = 0.002)和彗差(r = 0.688,P < 0.001)相关。

结论

与双焦点IOL相比,不同AL的白内障患者植入PanOptix三焦点IOL可显著提高视觉质量,表明其在临床上有很强的应用价值。

相似文献

本文引用的文献

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验