Comparative outcomes of mechanical and transepithelial PRK on the same excimer laser: A contralateral eye study.

作者信息

Rymer Priscila, Moscovici Bernardo Kaplan, Freitas Marcela Mara Silva, Schor Paulo, Campos Mauro

机构信息

Department of Ophthalmology and Visual Sciences, Federal University of Sao Paulo UNIFESP, São Paulo, Brazil.

Department of Ophthalmology, Hospital Visão Laser, Santos, Brazil.

出版信息

Eur J Ophthalmol. 2025 May;35(3):893-901. doi: 10.1177/11206721241278395. Epub 2024 Aug 22.

Abstract

PurposeCompare refractive results between mechanical PRK (mPRK) and transepithelial PRK (tPRK) with WaveLight Allegretto EX500 excimer laser system (Alcon Laboratories, Fort Worth, TX, USA).SettingDepartment of Ophthalmology of the Federal University of Sao Paulo, Brazil.DesignProspective and randomized study.MethodsIn 151 eyes of 73 patients with astigmatism and myopia, both eyes had similar refraction before surgery, with a maximum of 15-µm difference in ablation who underwent mPRK in one eye and tPRK in the contralateral eye. The mean age of the patients in this study was 31.45 ± 6.97 years (range, 22 to 54 years).ResultsA comparison was made with all variables between the two groups, and we found that UDVA and SE were worse in the tPRK group at six months than in the mPRK group. In the mPRK group, there was a higher frequency in the +/- 0.50 range and a lower frequency in the +/- 1.50 range. In the tPRK group, however, there was a lower frequency in the +/- 0.50 range and a higher frequency in the +/- 1.50 range. Concerning gain or loss of lines of sight, there was no association between the two groups (chi-square test, p = 0.887).ConclusionBoth mPRK and tPRK appear to have similar safety. However, mPRK was associated with significantly better UDVA and SE six months post-operatively.

摘要

目的

使用威视准分子激光系统(美国德克萨斯州沃思堡爱尔康实验室)比较机械性准分子原位角膜磨镶术(mPRK)和经上皮准分子原位角膜磨镶术(tPRK)的屈光结果。

地点

巴西圣保罗联邦大学眼科。

设计

前瞻性随机研究。

方法

在73例散光和近视患者的151只眼中,双眼术前屈光相似,消融量差异最大为15μm,其中一只眼行mPRK,对侧眼行tPRK。本研究中患者的平均年龄为31.45±6.97岁(范围22至54岁)。

结果

对两组间所有变量进行比较,我们发现tPRK组术后6个月的最佳矫正视力(UDVA)和等效球镜度(SE)比mPRK组差。在mPRK组中,±0.50范围的频率较高,±1.50范围的频率较低。然而,在tPRK组中,±0.50范围的频率较低,±1.50范围的频率较高。关于视力的增减,两组间无关联(卡方检验,p = 0.887)。

结论

mPRK和tPRK似乎具有相似的安全性。然而,mPRK术后6个月的UDVA和SE明显更好。