不同莫氏锥度种植体在低密度人工骨块中的初期稳定性评估:高速钻孔与低速钻孔的比较

Primary stability evaluation of different morse cone implants in low-density artificial bone blocks: A comparison between high-and low-speed drilling.

作者信息

Romasco Tea, De Bortoli Nilton, Paulo De Bortoli Joao, Jorge Jayme Sergio, Piattelli Adriano, Di Pietro Natalia

机构信息

Center for Advanced Studies and Technology-CAST, "G. D'Annunzio" University of Chieti-Pescara, Via Luigi Polacchi 11, 66100, Chieti, Italy.

Department of Neuroscience, Imaging and Clinical Sciences, "G. D'Annunzio" University of Chieti-Pescara, Via Dei Vestini 31, 66100, Chieti, Italy.

出版信息

Heliyon. 2024 Jul 27;10(15):e35225. doi: 10.1016/j.heliyon.2024.e35225. eCollection 2024 Aug 15.

Abstract

This study aimed to evaluate various biomechanical parameters associated with the primary stability of Maestro and Due Cone implants placed in low-density artificial bones, prepared using high-speed drilling with irrigation and low-speed drilling without irrigation. The insertion torque (IT), removal torque (RT), and implant stability quotient (ISQ) values were recorded for Maestro and Due Cone implants placed in low-density polyurethane blocks (10 and 20 pounds per cubic foot (PCF) with and without a cortical layer) prepared using high-speed and low-speed with or without irrigation using a saline solution, respectively. A three-way ANOVA model and Tukey's post-hoc test were conducted, presenting data as means and standard deviations. -values equal to or less than 0.05 were considered statistically significant. No statistically significant differences in IT, RT, and ISQ between drilling speeds were observed. However, Maestro implants exhibited lower IT and RT values after high- and low-speed drilling across almost all polyurethane blocks, significantly evident in the 20 PCF density block for IT and in the 20 PCF density block with the cortical layer for the RT with low-speed drilling (IT: 47.33 ± 10.02 Ncm and 16.00 ± 12.49 Ncm for Due Cone and Maestro implants, respectively, with p < 0.01; RT: 44.67 ± 22.81 Ncm and 20.01 ± 4.36 Ncm for Due Cone and Maestro implants, respectively, with p < 0.05) and among the same implant types inserted in different bone densities. Additionally, the study found that for all bone densities and drilling speeds, both implants registered ISQ values exceeding 60, except for the lowest-density polyurethane block. Overall, it can be inferred that low-speed drilling without irrigation achieved biomechanical parameters similar to conventional drilling with both implant types, even with lower IT values in the case of Maestro implants. These findings suggest a promising potential use of low-speed drilling without irrigation in specific clinical scenarios, particularly when focusing on preparation depth or when ensuring proper irrigation is challenging.

摘要

本研究旨在评估与Maestro和Due Cone种植体在低密度人工骨中的初期稳定性相关的各种生物力学参数,这些人工骨分别采用带冲洗的高速钻孔和不带冲洗的低速钻孔制备。记录了分别使用生理盐水带或不带冲洗的高速和低速制备的低密度聚氨酯块(每立方英尺10磅和20磅(PCF),有或无皮质层)中Maestro和Due Cone种植体的植入扭矩(IT)、取出扭矩(RT)和种植体稳定性商数(ISQ)值。进行了三因素方差分析模型和Tukey事后检验,数据以均值和标准差表示。p值等于或小于0.05被认为具有统计学意义。未观察到钻孔速度之间IT、RT和ISQ的统计学显著差异。然而,在几乎所有聚氨酯块中,Maestro种植体在高速和低速钻孔后的IT和RT值均较低,在20 PCF密度块中IT值以及在低速钻孔的有皮质层的20 PCF密度块中RT值差异显著(IT:Due Cone种植体和Maestro种植体分别为47.33±10.02 Ncm和16.00±12.49 Ncm,p<0.01;RT:Due Cone种植体和Maestro种植体分别为44.67±22.81 Ncm和20.01±4.36 Ncm,p<0.05),且在插入不同骨密度的相同种植体类型之间也存在差异。此外,研究发现,对于所有骨密度和钻孔速度,除了最低密度的聚氨酯块外,两种种植体的ISQ值均超过60。总体而言,可以推断,不带冲洗的低速钻孔获得的生物力学参数与两种种植体类型的传统钻孔相似,即使Maestro种植体的IT值较低。这些发现表明,不带冲洗的低速钻孔在特定临床场景中具有潜在的应用前景,特别是在关注制备深度或确保适当冲洗具有挑战性时。