Suppr超能文献

使用非侵入性设备对神经健康的儿科患者进行颅内顺应性分析的观察性研究。

Observational study of intracranial compliance analysis in neurologically healthy pediatric patients using a non-invasive device.

机构信息

Department of Medicine Course, Pequeno Príncipe Faculdades, Curitiba, Paraná, Brazil.

Department of Neurology, Hospital Pequeno Príncipe, Curitiba, PR, Brazil.

出版信息

Sci Rep. 2024 Aug 22;14(1):19482. doi: 10.1038/s41598-024-69938-8.

Abstract

Information about the morphology of the intracranial pressure waveform, as well as the variations in intracranial pressure (ICP) and compliance in pediatric patients are essential to diagnose and predict the progression of various neurological conditions. However, there is no information on the morphology of the IP waveform in neurologically healthy pediatric patients. In the present study, intracranial compliance was therefore analyzed in neurologically healthy patients with the aid of a noninvasive device. The study was an observational, cross-sectional study. Fifty-five neurologically healthy participants were included. Data on intracranial compliance with the patient in two positions, lying down (0°) and seated (45°), were collected with a noninvasive extracranial sensor, which allowed the intracranial pressure waveforms to be recorded. The values of the ratio P2/P1 were then analyzed. A questionnaire (with a scale from zero to ten, where ten corresponds to the highest level of satisfaction) was applied for patients to evaluate their satisfaction with the sensor. Patients were 10 years old (average), and most of them were (58%). Mean P2/P1 ratio was 0.94 (sd = 0.14) in the supine position and 0.91 (sd = 0.15) in the seated position. Participants were satisfied with the length of time for which the equipment was used (9.8, sd = 0.71). The device did not cause any discomfort. The noninvasive method used was well accepted by the patients. Intracranial compliance values were determined by analysis of the P2/P1 ratio in neurologically healthy pediatric population.Trial registration: Brazilian Registry of Clinical Trials Identifier: RBR-5j74ddg.

摘要

颅内压波形的形态以及小儿患者颅内压(ICP)和顺应性的变化对于诊断和预测各种神经状况的进展至关重要。然而,目前尚无关于神经健康的儿科患者颅内压波形形态的信息。因此,本研究借助一种非侵入性设备分析了神经健康患者的颅内顺应性。本研究为观察性、横断面研究。共纳入 55 例神经健康的参与者。使用非侵入性的颅外传感器收集患者处于两种体位(仰卧位[0°]和坐位[45°])时的颅内顺应性数据,允许记录颅内压波形。然后分析 P2/P1 比值。为患者应用问卷(评分从 0 到 10,其中 10 表示满意度最高),以评估他们对传感器的满意度。患者年龄为 10 岁(平均年龄),其中大多数为 58%。仰卧位时的平均 P2/P1 比值为 0.94(标准差[sd] = 0.14),坐位时为 0.91(sd = 0.15)。参与者对设备使用时间(9.8,sd = 0.71)的长度感到满意。该设备不会引起任何不适。患者对所使用的非侵入性方法接受程度良好。通过分析神经健康小儿人群中 P2/P1 比值确定颅内顺应性值。试验注册:巴西临床试验注册中心标识符:RBR-5j74ddg。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/2faf/11341783/ed997e1b3dae/41598_2024_69938_Fig1_HTML.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验