Suppr超能文献

保持准确性和扩大可及性:评估博图卡图简化乳腺 MRI 方案的疗效。

Maintaining accuracy and expanding access: evaluating the efficacy of the Botucatu Abbreviated Breast MRI Protocol.

机构信息

Department of Gynecology and Obstetrics Universidade Estadual Paulista "Júlio de Mesquita Filho" BotucatuSP Brazil Department of Gynecology and Obstetrics, Universidade Estadual Paulista "Júlio de Mesquita Filho", Botucatu, SP, Brazil.

Rede Mater Dei de Saúde e Redimama Belo HorizonteMG Brazil Rede Mater Dei de Saúde e Redimama, Belo Horizonte, MG, Brazil.

出版信息

Rev Bras Ginecol Obstet. 2024 Jul 26;46. doi: 10.61622/rbgo/2024rbgo55. eCollection 2024.

Abstract

OBJECTIVE

Our study evaluated the effectiveness of the Botucatu Abbreviated Protocol in breast magnetic resonance imaging (MRI) within Brazil's public healthcare system, focusing on its impact on patient access to MRI exams.

METHODS

This retrospective study involved 197 breast MRI exams of female patients over 18 years with histological breast carcinoma diagnosis, conducted at Hospital das Clínicas de Botucatu - UNESP between 2014 and 2018. Two experienced examiners prospectively and blindly analyzed the exams using an Integrated Picture Archiving and Communication System (PACS). They first evaluated the Botucatu Abbreviated Protocol, created from sequences of the complete protocol (PC), and after an average interval of 30 days, they reassessed the same 197 exams with the complete protocol. Dynamic and morphological characteristics of lesions were assessed according to BI-RADS 5th edition criteria. The study also analyzed the average number of monthly exams before and after the implementation of Botucatu Abbreviated Protocol.

RESULTS

The Botucatu Abbreviated Protocol showed high sensitivity (99% and 96%) and specificity (90.9% and 96%). There was a significant increase in the average monthly MRI exams from 6.62 to 23.8 post-implementation.

CONCLUSION

The Botucatu Abbreviated Protocol proved effective in maintaining diagnostic accuracy and improving accessibility to breast MRI exams, particularly in the public healthcare setting.

摘要

目的

本研究评估了巴西公共医疗体系中博图卡图简化协议在乳腺磁共振成像(MRI)中的有效性,重点关注其对患者接受 MRI 检查的影响。

方法

这是一项回顾性研究,共纳入了 197 例年龄在 18 岁以上且经组织学证实为乳腺癌的女性患者的乳腺 MRI 检查结果,这些检查均在 2014 年至 2018 年期间于博图卡图临床医院(巴西 UNESP 大学)进行。两名经验丰富的检查者使用综合影像归档与通信系统(PACS)对检查进行前瞻性和盲法分析。他们首先评估了简化协议(源自完整协议 PC 的序列),平均间隔 30 天后,他们使用完整协议重新评估了相同的 197 例检查。病变的动态和形态特征根据 BI-RADS 第 5 版标准进行评估。该研究还分析了实施博图卡图简化协议前后每月平均检查次数。

结果

简化协议显示出高的敏感性(99%和 96%)和特异性(90.9%和 96%)。实施简化协议后,平均每月 MRI 检查数量从 6.62 例增加到 23.8 例。

结论

博图卡图简化协议在维持诊断准确性和提高乳腺 MRI 检查可及性方面是有效的,特别是在公共医疗环境中。

相似文献

3
Implementation of abbreviated breast MRI in diagnostic and screening settings.简化乳腺MRI在诊断和筛查中的应用。
Acta Radiol. 2023 Mar;64(3):987-992. doi: 10.1177/02841851221114434. Epub 2022 Aug 7.
4
Breast MRI: Simplifying Protocol and BI-RADS Categories.乳腺 MRI:简化方案和 BI-RADS 分类。
Clin Breast Cancer. 2022 Jul;22(5):e615-e622. doi: 10.1016/j.clbc.2022.03.006. Epub 2022 Mar 24.
7
Abbreviated screening protocol for breast MRI: a feasibility study.乳腺MRI的简化筛查方案:一项可行性研究。
Acad Radiol. 2015 Sep;22(9):1157-62. doi: 10.1016/j.acra.2015.06.004. Epub 2015 Jul 4.

本文引用的文献

5
Cancer Progress and Priorities: Breast Cancer.癌症进展与优先事项:乳腺癌
Cancer Epidemiol Biomarkers Prev. 2021 May;30(5):822-844. doi: 10.1158/1055-9965.EPI-20-1193.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验