Suppr超能文献

特发性癫痫犬的扣带回 gyrus 半自动磁共振成像容积测量与发作间期痫样放电偏侧性的相关性。

Correlation between semiautomated magnetic resonance imaging volumetry of the cingulate gyrus and interictal epileptiform discharge lateralization in dogs with idiopathic epilepsy.

机构信息

Department of Internal Medicine and Clinic of Diseases of Horses, Dogs and Cats, Wrocław University of Environmental and Life Sciences, Wrocław, Poland.

NeuroTeam Specialist Veterinary Clinic, Wrocław, Poland.

出版信息

J Vet Intern Med. 2024 Sep-Oct;38(5):2590-2602. doi: 10.1111/jvim.17178. Epub 2024 Aug 27.

Abstract

BACKGROUND

Brain imaging suggests the involvement of the limbic system, particularly the cingulate gyrus (GC), in dogs with idiopathic epilepsy (IE).

HYPOTHESIS

A correlation exists between the side of interictal epileptiform discharges (IEDs) and the volume of the ipsilateral GC (GCe) in dogs with IE.

ANIMALS

Dogs admitted to the neurological consultation (32 with epileptic seizures and 13 control) were included.

METHODS

This retrospective, blinded study followed the International Veterinary Epilepsy Task Force recommendations for diagnosing IE at the Tier III confidence level. The IE group included 18 and 14 dogs with IEDs in the left and right hemispheres, respectively (median age: 36 months, median weight: 19.5 kg), whereas the control group included 13 dogs (median age: 32 months, median weight: 20 kg). Whole-brain and GC-volumetric assessments were performed by a semiautomated method.

RESULTS

In the control group, the volume of the GC was: left, from 743.63 to 1001.61 mm, right, from 789.35 to 1015.86 mm. In the study group, the volume of the GC was: left, from 720.88 to 1054.9 mm and right, from 566.29 to 987.77 mm. In dogs with IE, GCe volume was significantly lower than the mean volume of the GC in the control group relative to total intracranial volume (TIV; P = .00044).

CONCLUSIONS AND CLINICAL IMPORTANCE

Alterations in the volume of the GC provide insights into structural changes during IE. The use of semiautomatic volumetry provides an advantage by reducing the potential for human error.

摘要

背景

脑影像学研究表明,边缘系统,特别是扣带回(GC),与特发性癫痫(IE)犬的发作有关。

假设

IE 犬的发作间期癫痫样放电(IED)侧与同侧 GC(GCe)体积之间存在相关性。

动物

纳入接受神经学咨询的犬(32 只癫痫发作犬和 13 只对照犬)。

方法

本回顾性、盲法研究遵循国际兽医癫痫工作组(IEVF)诊断 IE 的 III 级置信度标准。IE 组包括 18 只和 14 只左侧和右侧半球有 IED 的犬(中位数年龄:36 个月,中位数体重:19.5kg),对照组包括 13 只犬(中位数年龄:32 个月,中位数体重:20kg)。全脑和 GC 体积评估采用半自动方法进行。

结果

对照组 GC 体积:左侧,743.63 至 1001.61mm;右侧,789.35 至 1015.86mm。研究组 GC 体积:左侧,720.88 至 1054.9mm;右侧,566.29 至 987.77mm。IE 犬的 GCe 体积明显低于对照组 GC 相对于总颅内体积(TIV)的平均体积(P=0.00044)。

结论和临床意义

GC 体积的改变为 IE 期间的结构变化提供了深入了解。半自动容积测量法的使用通过减少人为错误的可能性具有优势。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/3f53/11423450/e4e4293d087f/JVIM-38-2590-g003.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验