Therrien Camryn C, Ten Duis Kaj, Banierink Hester, de Vries Jean-Paul P M, Reininga Inge H F, IJpma Frank F A
Department of Trauma Surgery, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands.
Department of Surgery, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands.
Eur J Trauma Emerg Surg. 2024 Dec;50(6):2999-3005. doi: 10.1007/s00068-024-02652-2. Epub 2024 Aug 27.
To determine the relation between pelvic symmetry, as measured by the cross-measurement technique, and patient-reported outcome measures (PROMs) in terms of functional status and health-related quality of life.
In this prospective cohort study, X and Y measurements were taken according to the cross-measurement technique on AP radiographs of patients who were treated for an unstable pelvic ring injury in a level-1 trauma center. Patients completed PROMs at the time of admission (recalled pre-injury score) and one year following their injury, reporting their functional status with the Short Musculoskeletal Function Assessment (SMFA-NL), specifically the lower extremity dysfunction (LED), problems with daily activities (PDA) and mental and emotional problems (MEP) subscales, and quality of life with EuroQol-5D (EQ-5D). Subgroup analyses were also performed. PROMs were used to analyze the relation between pelvic symmetry and patient-reported outcome, using Spearman's Rank correlation coefficients.
A total of 130 patients (mean age 58 (SD18) years) with an unstable pelvic ring injury were included, of which 95 (73%) sustained type-B injuries and 35 (27%) type-C injuries. Sixty-three (49%) patients were treated operatively. The median pelvic symmetry ratio was 1.01 (IQR: 0.05). Weak or no correlations were found between the pelvic symmetry scores and the outcome measurements (Spearman's correlation coefficients: LED r = 0.09; PDA r = 0.11; MEP r=-0.02; and EQ-5D r=-0.08). Subgroup analyses revealed no correlations.
No significant relation was found between pelvic symmetry, measured radiologically, and functional status and health-related quality of life, one year following an unstable pelvic ring injury.
通过交叉测量技术测定骨盆对称性与患者报告的功能状态和健康相关生活质量结局指标(PROMs)之间的关系。
在这项前瞻性队列研究中,对在一级创伤中心接受不稳定骨盆环损伤治疗的患者的前后位X线片,采用交叉测量技术进行X和Y测量。患者在入院时(回忆伤前评分)和受伤后一年完成PROMs,用短肌肉骨骼功能评估量表(SMFA-NL)报告其功能状态,特别是下肢功能障碍(LED)、日常活动问题(PDA)和心理及情绪问题(MEP)子量表,并使用欧洲五维健康量表(EQ-5D)报告生活质量。还进行了亚组分析。使用Spearman等级相关系数,通过PROMs分析骨盆对称性与患者报告结局之间的关系。
共纳入130例不稳定骨盆环损伤患者(平均年龄58(标准差18)岁),其中95例(73%)为B型损伤,35例(27%)为C型损伤。63例(49%)患者接受了手术治疗。骨盆对称比中位数为1.01(四分位间距:0.05)。骨盆对称评分与结局测量之间发现弱相关性或无相关性(Spearman相关系数:LED r = 0.09;PDA r = 0.11;MEP r = -0.02;EQ-5D r = -0.08)。亚组分析未发现相关性。
不稳定骨盆环损伤一年后,经放射学测量的骨盆对称性与功能状态和健康相关生活质量之间未发现显著关系。