Abstract

BACKGROUND

Monitoring of diabetes by measuring capillary blood glucose using a glucometer.

OBJECTIVES

To compare the three most used glucose meters in diabetic patients in a maternity and neonatal center in terms of repeatability, accuracy, and stability.

METHODOLOGY

A comparative study on 100 diabetic patients admitted to the various departments of a maternity and neonatal center. For each patient, a capillary measurement was made using each of the three glucometers to be tested (Accucheck, On Call and Bionime) as well as a blood glucose on venous blood, performed in the laboratory using the Siemens X brand plus PLC (reference method). The same sample was used to carry out all measurements.

RESULTS AND CONCLUSIONS

The Accucheck brand reader and the On Call brand thus, show a better correlation for open and closed bottles of test strips'storage, compared with the Bionime brand reader. We found that the Accucheck and On Call readers are comparable in terms of reliability of results and are better than the Bionime brand reader. We have found that, first using closed vials give more accurate results for glycemia readers and also, On Call and Accucheck brand readers are more reliable and accurate than the Bionime brand reader.

摘要

背景

使用血糖仪测量毛细血管血糖以监测糖尿病。

目的

在一家母婴中心比较三种最常用血糖仪在糖尿病患者中的重复性、准确性和稳定性。

方法

对一家母婴中心各科室收治的100例糖尿病患者进行比较研究。对每位患者,使用三种待测试的血糖仪(罗氏卓越型、安易血糖仪和必诺美血糖仪)分别进行一次毛细血管测量,同时在实验室使用西门子X品牌加PLC(参考方法)检测静脉血血糖。所有测量均使用同一样本。

结果与结论

与必诺美品牌血糖仪相比,罗氏卓越型血糖仪和安易血糖仪在试纸条开瓶和闭瓶储存方面显示出更好的相关性。我们发现,罗氏卓越型血糖仪和安易血糖仪在结果可靠性方面相当,且优于必诺美品牌血糖仪。我们还发现,首先,使用闭瓶对血糖仪测量血糖能得出更准确的结果,其次,安易血糖仪和罗氏卓越型血糖仪比必诺美品牌血糖仪更可靠、更准确。