Murdock D K, Johnson S A, Loeb H S, Scanlon P J
Cathet Cardiovasc Diagn. 1985;11(2):153-9. doi: 10.1002/ccd.1810110206.
The intracoronary injection of contrast media during coronary angiography occasionally results in ventricular fibrillation. Experimental studies have implicated the calcium sequestering agents, sodium citrate and EDTA in Renografin 76 (RG76), as contributing to this complication. Angiovist 370 (AV370) is a contrast medium similar to RG76 except that it contains disodium calcium EDTA instead of EDTA and sodium citrate. To determine if contrast media lacking sodium citrate and EDTA will result in a lower incidence of ventricular fibrillation in man, this investigation compared the incidence of contrast media-induced ventricular fibrillation in patients undergoing coronary angiography with RG76 to that with AV370. Group A consisted of 2,500 consecutive patients undergoing coronary angiography with RG76 and group B consisted of 2,000 subsequent consecutive patients in whom AV370 was employed as the contrast medium. There was no significant difference between groups A and B with respect to the volume of contrast media used per patient (153 +/- 49 ml vs 154 +/- 45ml), age (58.4 +/- 10 vs 58.6 +/- 10 years), sex (70% male vs 70% male), ejection fraction (59 +/- 17 vs 60 +/- 20), history of mitral valve disease (5.8% vs 7.1%), history of aortic valve disease (6.7% vs 6.5%), prior coronary artery bypass graft surgery (6.6% vs 7.3%), or extent of coronary artery disease. Fifteen episodes of contrast media-induced ventricular fibrillation occurred in group A (incidence 0.6%) whereas two episodes occurred in group B (incidence 0.1%) (p less than 0.02). Each patient was successfully defibrillated and no adverse sequelae resulted. Thus the present investigation suggests that the incidence of ventricular fibrillation during coronary angiography can be significantly decreased by using contrast media lacking sodium citrate and EDTA.
冠状动脉造影期间冠状动脉内注射造影剂偶尔会导致心室颤动。实验研究表明,Renografin 76(RG76)中的钙螯合剂柠檬酸钠和乙二胺四乙酸(EDTA)是导致这一并发症的原因。Angiovist 370(AV370)是一种与RG76类似的造影剂,不同之处在于它含有乙二胺四乙酸二钠钙而不是EDTA和柠檬酸钠。为了确定缺乏柠檬酸钠和EDTA的造影剂是否会降低人体心室颤动的发生率,本研究比较了接受冠状动脉造影的患者使用RG76和AV370时造影剂诱发心室颤动的发生率。A组由2500例连续接受RG76冠状动脉造影的患者组成,B组由随后连续2000例使用AV370作为造影剂的患者组成。A组和B组在每位患者使用的造影剂体积(153±49ml对154±45ml)、年龄(58.4±10对58.6±10岁)、性别(70%为男性对70%为男性)、射血分数(59±17对60±20)、二尖瓣疾病史(5.8%对7.1%)、主动脉瓣疾病史(6.7%对6.5%)、既往冠状动脉搭桥手术史(6.6%对7.3%)或冠状动脉疾病程度方面没有显著差异。A组发生了15次造影剂诱发的心室颤动(发生率0.6%),而B组发生了2次(发生率0.1%)(p<0.02)。每位患者均成功除颤,未产生不良后遗症。因此,本研究表明,使用缺乏柠檬酸钠和EDTA的造影剂可显著降低冠状动脉造影期间心室颤动的发生率。