冠状动脉造影期间的心室颤动:使用非离子型造影剂可降低发生率。

Ventricular fibrillation during coronary angiography: reduced incidence with nonionic contrast media.

作者信息

Missri J, Jeresaty R M

机构信息

Section of Cardiology, Saint Francis Hospital and Medical Center, Hartford, Connecticut.

出版信息

Cathet Cardiovasc Diagn. 1990 Jan;19(1):4-7. doi: 10.1002/ccd.1810190103.

Abstract

Ventricular fibrillation during coronary angiography with Renografin-76 has been attributed to the high osmolar ionic and calcium binding additive properties. Isovue-370 is a new low osmolar nonionic contrast medium lacking calcium binding additives. The present investigation compared the incidence of contrast media-induced ventricular fibrillation in patients undergoing coronary angiography with Renografin-76 to that with Isovue-370. Group I consisted of 2,000 consecutive patients undergoing coronary angiography with Renografin-76, and group II consisted of 2,000 subsequent consecutive patients in whom Isovue-370 was employed as the contrast medium. There was no significant difference between groups I and II with respect to volume of contrast media used per patient (125 +/- 35 vs. 140 +/- 45 ml), age (63.5 +/- 15 vs. 60 +/- 17 years), sex (74% male vs. 76% male), ejection fraction (55% vs. 55%), valvular heart disease (8% vs. 9%), prior coronary artery bypass graft surgery (5.8% vs. 5%), or extent of coronary artery disease. Contrast media-induced ventricular fibrillation occurred in 20 patients in group I (incidence 1%), whereas eight episodes occurred in group II (incidence 0.4%) (P less than 0.03). Thus the present investigation suggests that the incidence of ventricular fibrillation during coronary angiography can be significantly decreased by using low osmolar nonionic contrast media lacking calcium binding additives.

摘要

使用泛影葡胺-76进行冠状动脉造影期间发生的心室颤动被归因于其高渗性、离子性和钙结合添加剂特性。碘克沙醇-370是一种新型低渗非离子型造影剂,不含钙结合添加剂。本研究比较了使用泛影葡胺-76和碘克沙醇-370进行冠状动脉造影的患者中造影剂诱发心室颤动的发生率。第一组由2000例连续使用泛影葡胺-76进行冠状动脉造影的患者组成,第二组由随后连续2000例使用碘克沙醇-370作为造影剂的患者组成。第一组和第二组在每位患者使用的造影剂体积(125±35 vs. 140±45 ml)、年龄(63.5±15 vs. 60±17岁)、性别(男性74% vs. 76%)、射血分数(55% vs. 55%)、瓣膜性心脏病(8% vs. 9%)、既往冠状动脉旁路移植手术(5.8% vs. 5%)或冠状动脉疾病程度方面无显著差异。第一组有20例患者发生造影剂诱发的心室颤动(发生率1%),而第二组有8例发作(发生率0.4%)(P<0.03)。因此,本研究表明,使用不含钙结合添加剂的低渗非离子型造影剂可显著降低冠状动脉造影期间心室颤动的发生率。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验