Suppr超能文献

三种不同旋转锉系统在根管预备时对根尖碎屑推出作用的比较评价。

Comparative evaluation of apical debris extrusion during root canal preparation using three different rotary file systems.

机构信息

Datta Meghe Institute of Higher Education and Research, Sawangi, Maharashtra, India.

Department of Conservative Dentistry and Endodontics, Sharad Pawar Dental College, Wardha, Maharshtra, 442001, India.

出版信息

F1000Res. 2023 Oct 6;12:797. doi: 10.12688/f1000research.135235.2. eCollection 2023.

Abstract

: Endodontic success depends on the complete cleaning and shaping of the root canal. In order to achieve this goal, debris removal is essential. Even with improvements in instrument design, apical debris extrusion continues to be a cause of periradicular inflammation. The current study aimed to compare the amount of apically extruded debris throughout the canal instrumentation with TruNatomy, ProTaper Next, 2Shape rotary systems. : A total of 60 freshly extracted single‑rooted mandibular premolars were used. An access opening was made, and a working length was estimated. The samples were arbitrarily allocated into three groups Group I: TruNatomy (n = 20), Group II: ProTaper Next (n = 20), Group III: 2Shape (n = 20). During the canal instrumentation, the extruded debris were collected in preweighed Eppendorf tubes. Post-instrumentation, the tubes were placed in a hot air oven at 140°C for five hours. For calculating the dry debris weight, the tube's pre-instrumentation weight was deducted from the post-instrumentation weight. The data was analysed using one‑way analysis of variance and Tukey's test. : Extrusion of debris was noted in all the specimens. TruNatomy rotary system showed least debris extrusion in comparison to ProTaper Next and 2Shape (P < 0.05). However, the results were statistically non-significant between ProTaper Next and 2Shape (P > 0.05). : It was noted that all instruments apically extruded debris, with TruNatomy system being related to minimum extrusion.

摘要

: 根管治疗的成功取决于根管的彻底清洁和成形。为了实现这一目标,去除碎屑是必不可少的。即使器械设计有所改进,根尖碎屑的挤出仍然是根尖周围炎症的一个原因。本研究旨在比较 TruNatomy、ProTaper Next、2Shape 旋转系统在根管预备过程中整个根管内的根尖挤出物量。: 共使用 60 颗新鲜拔出的下颌前磨牙。进行了一个开口,估计了一个工作长度。将样本任意分配到三组:组 I:TruNatomy(n = 20),组 II:ProTaper Next(n = 20),组 III:2Shape(n = 20)。在根管预备过程中,将挤出的碎屑收集在预先称重的 Eppendorf 管中。预备后,将管放入 140°C 的热空气烤箱中 5 小时。为了计算干燥的碎屑重量,从预备前的管重中减去预备后的管重。使用单向方差分析和 Tukey 检验对数据进行分析。: 所有标本均有碎屑挤出。与 ProTaper Next 和 2Shape 相比,TruNatomy 旋转系统的碎屑挤出量最少(P<0.05)。然而,ProTaper Next 和 2Shape 之间的结果在统计学上无显著差异(P>0.05)。: 所有器械都有根尖挤出物,TruNatomy 系统与最小挤出物相关。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/7180/11362742/c0b3b9ff5646/f1000research-12-156987-g0000.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验