Ophthalmology Unit, DIMEC, Alma Mater Studiorum Università di Bologna, Bologna, Italy.
IRCCS Azienda Ospedaliero-Universitaria di Bologna, Bologna, Italy.
Eye (Lond). 2024 Oct;38(15):2932-2938. doi: 10.1038/s41433-024-03191-1. Epub 2024 Sep 2.
To study the density, spacing, and regularity of retinal cone photoreceptors using an Adaptive Optics (AO) retinal camera (Rtx1, Imagine Eyes, Orsay, France) in patients with Primary Open Angle Glaucoma (POAG) and to compare the outcomes with those of healthy age-matched control subjects.
The study included 43 eyes with POAG and 31 eyes of normal subjects. POAG patients were divided into three groups according to the severity of the visual field defect. The AO Rtx1 was used to obtain images of the parafoveal cone mosaic to calculate cone values. Analysis was performed at two and four degrees of eccentricity from the fovea along the four meridians (nasal, temporal, superior, inferior).
In POAG eyes, the mean ± standard deviation (SD) cone density at 2° considering all meridians was significantly lower than in normal controls (23,058.6 ± 3532.0 cones/mm, and 25,511.7 ± 3157.5 cones/mm, respectively; p = 0.003). Cone spacing was 7.3 ± 0.5 µm in POAG and 7.0 ± 0.4 µm in normal controls (p = 0.005), and cone regularity was 90.5 ± 4.9% and 93.5 ± 1.9% in POAG and normal controls, respectively (p < 0.001). At 4° similar trends were observed. However, no significant differences were found among patients with different severity of POAG (p > 0.05).
Using AO Rtx1, significant differences in retinal photoreceptors mosaic pattern were found between POAG eyes and age-matched controls, indicating a reduction in photoreceptors in POAG. No significant differences in retinal photoreceptor values were found among the three POAG groups.
使用自适应光学(AO)视网膜相机(Rtx1,Imagine Eyes,Orsay,法国)研究原发性开角型青光眼(POAG)患者的视网膜锥光感受器的密度、间距和规则性,并将结果与年龄匹配的健康对照组进行比较。
本研究纳入 43 只 POAG 眼和 31 只正常眼。根据视野缺损的严重程度,将 POAG 患者分为三组。使用 AO Rtx1 获取旁中心锥光感受器镶嵌图像以计算锥光感受器值。在距黄斑中心凹鼻侧、颞侧、上侧和下侧四个子午线的 2°和 4°处进行分析。
在 POAG 眼中,考虑所有子午线时,2°处的平均标准偏差(SD)锥光感受器密度明显低于正常对照组(分别为 23058.6±3532.0 个/毫米和 25511.7±3157.5 个/毫米;p=0.003)。POAG 中的锥光感受器间距为 7.3±0.5μm,正常对照组为 7.0±0.4μm(p=0.005),POAG 和正常对照组的锥光感受器规则性分别为 90.5±4.9%和 93.5±1.9%(p<0.001)。在 4°处也观察到类似的趋势。然而,不同严重程度的 POAG 患者之间无显著差异(p>0.05)。
使用 AO Rtx1,发现 POAG 眼与年龄匹配的对照组之间视网膜光感受器镶嵌模式存在显著差异,表明 POAG 中光感受器减少。在三组 POAG 患者中,视网膜光感受器值无显著差异。