Suppr超能文献

通过研究缓冲体系的影响简便测定工业卤水中的铝含量

Facile Determination of Aluminum Content in Industrial Brine by Investigating the Effects of Buffer Systems.

作者信息

Csorba Benjámin, Farkas László, Csécsi Marcell, Mika László T, Gresits Iván L

机构信息

Department of Chemical and Environmental Process Engineering, Faculty of Chemical Technology and Biotechnology, Budapest University of Technology and Economics, Műegyetem rkp. 3., H-1111, Budapest, Hungary.

Process Technology Support, BorsodChem Ltd., Bolyai tér 1., H-3700, Kazincbarcika, Hungary.

出版信息

ChemistryOpen. 2024 Dec;13(12):e202400038. doi: 10.1002/open.202400038. Epub 2024 Sep 3.

Abstract

The aluminum content of concentrated (27 wt%) sodium chloride solutions could be crucial for large-scale chlor-alkali-based industries applying membrane cell electrolysis. Thus, a facile method which enables a fast and reliable protocol to determine the Al content of these solutions on ppb scale in industrial environments is fundamentally important. It was demonstrated that the increased sensitivity of colorful Al-ECR (eriochrome cyanine R) complex by the use of a cationic surfactant and specific biological buffers could effectively indicate the Al content in an extended pH interval of a concentrated saline medium under industrial conditions. The dependence of the analytical protocol on pH, temperature, time, wavelength, and the salinity of the medium was investigated. It was shown that the absorbance-based measurements of the solution should be performed at least 2-4 h after its preparation. By applying the selected two Good's buffers (HEPES: 4-(2-hydroxyethyl)-1-piperazineethanesulfonic acid, MOPS: 3-(N-morpholino)-propanesulfonic acid) and Tris (tris(hydroxymethyl)aminomethane), 32.8-38.1 % increase in the sensitivity was achieved for saturated NaCl solutions. Moreover, the limits of detection and quantification (LOD, LOQ) were also lowered by 19.0-29.8 %, and the salinity dependence of the calibration was also reduced.

摘要

对于采用膜电解槽的大规模氯碱工业来说,浓缩(27 wt%)氯化钠溶液中的铝含量可能至关重要。因此,在工业环境中,一种能够快速、可靠地测定这些溶液中十亿分之一级铝含量的简便方法至关重要。结果表明,通过使用阳离子表面活性剂和特定生物缓冲剂提高彩色铝-铬菁R(ECR)络合物的灵敏度,能够在工业条件下浓缩盐介质的扩展pH区间内有效指示铝含量。研究了分析方法对pH、温度、时间、波长和介质盐度的依赖性。结果表明,基于吸光度的溶液测量应在制备后至少2 - 4小时进行。通过应用选定的两种Good's缓冲剂(HEPES:4-(2-羟乙基)-1-哌嗪乙磺酸,MOPS:3-(N-吗啉基)-丙磺酸)和Tris(三(羟甲基)氨基甲烷),饱和氯化钠溶液的灵敏度提高了32.8 - 38.1%。此外,检测限和定量限(LOD,LOQ)也降低了19.0 - 29.8%,校准的盐度依赖性也降低了。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/ebd3/11625942/7760061bab09/OPEN-13-e202400038-g007.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验