低能量730纳米皮秒激光治疗中国患者黄褐斑的疗效与安全性

Efficacy and Safety of Low-Fluence 730-nm Picosecond Laser in the Treatment of Melasma in Chinese Patients.

作者信息

Han Rui, Sun Yifang, Su Mingshan

机构信息

All authors are affiliated with the Dr Su Medical Cosmetic Clinic, Beijing, China.

出版信息

Dermatol Surg. 2025 Feb 1;51(2):166-170. doi: 10.1097/DSS.0000000000004393. Epub 2024 Sep 4.

Abstract

BACKGROUND

The 730-nm picosecond laser has shown promise in treating various benign pigmentary conditions, and it is yet to be determined whether it is effective and safe for melasma.

OBJECTIVE

The aim of this study was to investigate the potential benefits and risks of using the 730-nm picosecond laser to remove melasma.

MATERIALS AND METHODS

This is a retrospective review of all patients who presented to the clinic between April 2021 and April 2022 for the treatment of melasma with 730-nm picosecond laser alone. The efficacy of the laser was assessed based on the Melasma Area and Severity Index (MASI) score using high-resolution photographs evaluated by blinded dermatologists.

RESULTS

A total of 25 Chinese with Fitzpatrick skin Type II to IV were included. Patients were treated for an average of 3.56 ± 0.77 treatment sessions. The mean MASI scores decreased by 33.7% from 11.38 ± 6.60 to 7.55 ± 6.08 at an average of 8.48 ± 2.16 weeks of follow-up ( p < .001). Among the patients, 1 experienced a 79% decrease, 6 had a decrease ranging from 51% to 75%, 10 had a decrease ranging from 26% to 50%, 5 had a decrease of less than 25%, and 3 experienced no changes in MASI scores. No hyper/hypopigmentation was observed.

CONCLUSION

Low-fluence 730-nm picosecond laser is an effective and safe modality for the treatment of melasma in Chinese patients.

摘要

背景

730纳米皮秒激光在治疗各种良性色素沉着性疾病方面已显示出前景,但对于黄褐斑的治疗是否有效和安全尚待确定。

目的

本研究旨在探讨使用730纳米皮秒激光去除黄褐斑的潜在益处和风险。

材料与方法

这是一项对2021年4月至2022年4月期间仅使用730纳米皮秒激光到诊所治疗黄褐斑的所有患者的回顾性研究。基于黄褐斑面积和严重程度指数(MASI)评分,通过由不知情的皮肤科医生评估的高分辨率照片来评估激光的疗效。

结果

共纳入25名皮肤菲茨帕特里克分型为II至IV型的中国患者。患者平均接受了3.56±0.77次治疗。在平均8.48±2.16周的随访中,平均MASI评分从11.38±6.60降至7.55±6.08,下降了33.7%(p<.001)。其中,1例患者下降了79%,6例下降幅度在51%至75%之间,10例下降幅度在26%至50%之间,5例下降幅度小于25%,3例患者的MASI评分无变化。未观察到色素沉着过度/色素沉着不足。

结论

低能量密度的730纳米皮秒激光是治疗中国患者黄褐斑的一种有效且安全的方式。