Suppr超能文献

生物力学评估一种实验性的内环固定器(RingFix)在骨质疏松骨模型上稳定骨盆环损伤的效果。

Biomechanical evaluation of an experimental internal ring fixator (RingFix) for stabilization of pelvic ring injuries on an osteoporotic bone model.

机构信息

Department of Orthopaedics and Traumatology, University Medical Center, Langenbeckstraße 1, 55131, Mainz, Germany.

Departement of Orthopedics and Tramatology, Lausanne University Hospital, Rue du Bugnon 46, 1011, Lausanne, Switzerland.

出版信息

Sci Rep. 2024 Sep 6;14(1):20823. doi: 10.1038/s41598-024-71138-3.

Abstract

During the last decades, effective pain reduction and early mobilization were identified as the central priorities in therapy of insufficiency fractures of the pelvis. For operative treatment minimally-invasive stabilization techniques are favored. While there is consensus on the significance of sufficient dorsal stabilization the role of additional fixation of the anterior fracture component stays under discussion. Within the present study we developed an internal ring fixator system (RingFix) with the question whether an in-itself-closed construct can improve stability of the entire ring structure. RingFix was evaluated on an osteoporotic bone model with a standardized FFP IIIc fracture within an established biomechanical setup regarding its primary stabilization potential. Further, it was compared to transiliac-transsacral screw fixation with and without stabilization of the anterior fracture component. The transiliac-transsacral fixation with separate screw fixation of the anterior fracture showed significantly higher stability than the RingFix and the transiliac-transsacral screw fixation without anterior stabilization. Our results show that stabilization of the anterior fracture component relevantly improves the stability of the entire ring construct. As a bridging stabilizer, RingFix shows biomechanical advantages over an isolated dorsal fracture fixation, but inferior results than direct stabilization of the single fracture components.

摘要

在过去的几十年中,有效减轻疼痛和早期活动被确定为治疗骨盆不稳定性骨折的核心重点。对于手术治疗,微创稳定技术是首选。虽然对于充分的背侧稳定的重要性已经达成共识,但对于前侧骨折部分的额外固定的作用仍存在争议。在本研究中,我们开发了一种内环固定器系统(RingFix),旨在探讨这种自封闭结构是否能提高整个环结构的稳定性。我们在一个骨质疏松骨模型上,使用标准化的 FFP IIIc 骨折模型,在既定的生物力学设置下,评估了 RingFix 的初步稳定潜力。进一步将其与经髂骨-经骶骨螺钉固定进行比较,包括是否固定前侧骨折部分。与不固定前侧骨折部分的经髂骨-经骶骨螺钉固定相比,单独固定前侧骨折部分的经髂骨-经骶骨螺钉固定具有更高的稳定性。我们的结果表明,固定前侧骨折部分可显著提高整个环结构的稳定性。作为一种桥接稳定器,RingFix 在生物力学上优于单纯的背侧骨折固定,但不如直接固定单个骨折部分的效果好。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/b263/11379716/a47101b42815/41598_2024_71138_Fig1_HTML.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验