心房壁射频消融损伤:其变化程度如何?猪模型中9.4特斯拉磁共振成像对射频消融损伤体积的分析。

Radiofrequency Lesion in the Atrial Wall: How Variable Is It? 9.4 Tesla MRI Analysis of Radiofrequency Lesion Volume in a Swine Model.

作者信息

Cardelli Laura Sofia, Laumont Thomas, Beghian July, Achahli Yosra, Cardoso Maida, Bacle Marylène, Pasquié Jean-Luc, Granier Mathieu

机构信息

Département de Cardiologie, Centre Hospitalier Régional Universitaire de Montpellier, 34295 Montpellier, France.

Cardiology Department, Versilia Hospital, 55041 Camaiore, Italy.

出版信息

J Clin Med. 2024 Aug 30;13(17):5153. doi: 10.3390/jcm13175153.

Abstract

: Most data on radiofrequency (RF) effects come from ex vivo or in vitro studies that quantify lesions using width and/or depth, while electrophysiologists use manufacturers' indirect indices. The objective of this study was to evaluate RF lesion volume by high-resolution MRI of excised lesions in an in vivo porcine model, comparing a low-energy long-duration (LE) (20 W, 50 s) RF application strategy with a high-energy short-duration (HE) (50 W, 20 s) one. : Eighteen piglets were divided into LE (n = 9) and HE groups (n = 9). RF applications were performed at four locations in both atria. Animals were sacrificed after 5-7 days, and RF lesion specimens were excised, fixed, and analyzed by 9.4 Tesla MRI. RF lesion volume, variability (variance), depth, and any extracardiac lesions were compared between the groups. : Seventy RF applications were performed (36 LE, 34 HE). MRI analyzed 26 LE and 28 HE samples. The HE group showed 35% higher volume than the LE group (100.2 mm (±81.2) in LE vs. 178.3 mm (±163.7) in HE, = 0.033). RF volume variance was 6.6 mm in LE and 40.3 mm in HE. The HE group had more complications (seven vs. zero, = 0.02) and extracardiac lesions (18 vs. 14, = 0.613). : There was large and unpredictable variability in RF injury on the atrial wall, even under controlled conditions, which could explain arrhythmia recurrences. The greatest lesion variability was found during HE applications. The dose/effect relationship of RF needs careful study for treating cardiac arrhythmias.

摘要

大多数关于射频(RF)效应的数据来自体外或体内研究,这些研究使用宽度和/或深度来量化损伤,而电生理学家则使用制造商的间接指标。本研究的目的是通过对体内猪模型中切除的损伤进行高分辨率MRI来评估RF损伤体积,将低能量长时间(LE)(20W,50秒)的RF应用策略与高能量短时间(HE)(50W,20秒)的策略进行比较。18只仔猪被分为LE组(n = 9)和HE组(n = 9)。在两个心房的四个位置进行RF应用。5 - 7天后处死动物,切除RF损伤标本,固定并通过9.4特斯拉MRI进行分析。比较两组之间的RF损伤体积、变异性(方差)、深度以及任何心外损伤。共进行了70次RF应用(36次LE,34次HE)。MRI分析了26个LE样本和28个HE样本。HE组的体积比LE组高35%(LE组为100.2立方毫米(±81.2),HE组为178.3立方毫米(±163.7),P = 0.033)。RF体积方差在LE组为6.6立方毫米,在HE组为40.3立方毫米。HE组有更多并发症(7例对0例,P = 0.02)和心外损伤(18处对14处,P = 0.613)。即使在受控条件下,心房壁上的RF损伤也存在很大且不可预测的变异性,这可能解释心律失常的复发。在HE应用期间发现最大的损伤变异性。RF的剂量/效应关系在治疗心律失常时需要仔细研究。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/b1cf/11396762/408b06732a60/jcm-13-05153-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验