Abstract

Implantable devices (implanted pump/implanted catheter and port) are recommended for continuous epidural application of opiates or local anaesthetics in order to reduce hygienic problems during long term epidural medication. No signs of contamination could be found during bacteriologic culture of residual volumes of 30 patients treated with epidural drug delivery systems and of samples collected during an in vitro investigation (incubation of filled external pump systems at body temperature/storage of syringes with a premixed solution of opiate and local anaesthetic for repeated epidural bolus application). As demonstrated in a case report prophylactic antibiotic coverage prior to implantation may be necessary in patients with a preexisting susceptibility to infection. The concentrations of morphine (radioimmuno-assay) and of bupivacaine (gas-solid chromatography) within the reservoir were stable during clinical therapy as well as during the in vitro experiments.

摘要

为减少长期硬膜外用药期间的卫生问题,推荐使用可植入装置(植入式泵/植入式导管和端口)持续硬膜外应用阿片类药物或局部麻醉剂。在对30例接受硬膜外给药系统治疗的患者的残留量进行细菌培养以及在体外研究(将填充的外部泵系统在体温下孵育/储存含有阿片类药物和局部麻醉剂预混溶液的注射器以进行重复硬膜外推注)期间收集的样本中,未发现污染迹象。如一份病例报告所示,对于先前存在感染易感性的患者,植入前可能需要预防性使用抗生素。在临床治疗以及体外实验期间,储液器内吗啡(放射免疫测定)和布比卡因(气固色谱法)的浓度均保持稳定。