UNLABELLED

There is a clear medical need for an accurate diagnostic test for typhoid that can be performed at point of care. Two antigens (lipopolysaccharide [LPS] and hemolysin E [HlyE]) have recently been identified that can distinguish typhoid from other bacterial infections. Here, we present the results of a diagnostic accuracy study of the Dual Path Platform (DPP) Typhoid assay (Chembio) that detects IgA to both LPS and HlyE using blood culture as the reference standard. This was a retrospective, observational, laboratory study conducted at the Aga Khan University research laboratory, Pakistan, to evaluate the sensitivity and specificity of the DPP Typhoid assay, using archived frozen serum samples collected during a previous typhoid diagnostic accuracy study (NCT04801602). The sensitivity, specificity, and accuracy (area under the receptor operating characteristics curve [AUC]) were then assessed using the manufacturer's and Youden's optimal thresholds. In total, 385 samples were included in the analysis. Using the manufacturer's thresholds, the sensitivity, specificity, and AUC were 97.8% (95% confidence interval [CI] 94.6-99.2), 65.3% (95% CI 58.5-71.6), and 81.5% (95% CI 75.5-85.3), respectively. At Youden's optimal threshold, the overall sensitivity of the DPP Typhoid assay was 89.7% and the specificity was 82.2%. In latent class modeling compared with other nine rapid diagnostic tests evaluated from the same cohort sample, the DPP Typhoid assay demonstrated the highest balanced accuracy (89.2%). The DPP Typhoid assay demonstrated a high diagnostic accuracy for typhoid fever. However, further adjustment to new thresholds is recommended to enhance its performance capabilities.

IMPORTANCE

Currently available diagnostic tests for typhoid have several limitations, including low sensitivity and specificity. Dual Path Platform Typhoid assay is a multiplex rapid test that detects IgA antibodies to lipopolysaccharide and hemolysin E antigen. It is considered to have high sensitivity and specificity, and its results were found to be highly correlated with ELISA results. However, very few studies have been conducted to evaluate this test and limited information about the accuracy of this test is present. Hence, this study evaluated the new typhoid test.

摘要

目的

目前用于伤寒的诊断检测方法存在一些局限性,包括灵敏度和特异性低。双路径平台(DPP)伤寒检测法(Chembio)是一种多重快速检测法,可检测到针对脂多糖和溶血素 E 抗原的 IgA 抗体。该检测法被认为具有较高的灵敏度和特异性,且其结果与 ELISA 结果高度相关。但是,很少有研究评估过该检测法,目前有关该检测法准确性的信息也有限。因此,本研究对新的伤寒检测法进行了评估。

相似文献

6
Rapid diagnostic tests for typhoid and paratyphoid (enteric) fever.伤寒和副伤寒(肠道)热的快速诊断检测
Cochrane Database Syst Rev. 2017 May 26;5(5):CD008892. doi: 10.1002/14651858.CD008892.pub2.

本文引用的文献

6
Progress in Typhoid Fever Epidemiology.伤寒流行病学的进展。
Clin Infect Dis. 2019 Feb 15;68(Suppl 1):S4-S9. doi: 10.1093/cid/ciy846.
9
Rapid diagnostic tests for typhoid and paratyphoid (enteric) fever.伤寒和副伤寒(肠道)热的快速诊断检测
Cochrane Database Syst Rev. 2017 May 26;5(5):CD008892. doi: 10.1002/14651858.CD008892.pub2.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验