A systematic evaluation of five different image-derived input functions for the clinical implementation of F-NaF bone PET/CT in patients with chronic kidney disease-mineral and bone disorder.

作者信息

Theil Jørn, Vrist Marie Houmaa, Bech Jesper Nørgaard, Fynbo Claire Anne

机构信息

Department of Nuclear Medicine, Gødstrup Hospital, Herning, Denmark.

Department of Clinical Medicine, Aarhus University, Aarhus, Denmark.

出版信息

Front Nucl Med. 2023 Jul 28;3:1235800. doi: 10.3389/fnume.2023.1235800. eCollection 2023.

Abstract

INTRODUCTION

The aim of this study was to investigate the impact of the use of varying input parameters on resulting bone plasma clearance ( ) and other kinetic modelling parameters in a group of patients with chronic kidney disease-mineral and bone disorder (CKD-MBD).

METHODS

Raw PET/CT data and blood data were systematically analyzed using five different VOIs for the input functions in the left ventricle and in the thoracic aorta. Standardized VOIs were placed in four thoracic vertebrae and the results pooled and averaged. The basic image-derived input functions (IDIFs) were corrected for partial volume effect and spill-over and modified by substitution of the terminal image exponential with the corresponding plasma-exponentials derived from blood samples. was then calculated using both a non-linear regression (NLR) analysis and a graphical Patlak analysis and compared.

RESULTS

Our original results were reproducible with an inter-observer difference of approximately 6%. The correction factors varied with the VOI volumes from 0.73 ± 0.17 for the largest LV-VOI (48.7 ± 25.3 cm) to 0.99 ± 0.10 for the AO-VOI (3.4 ± 1.2 cm). The mean NLR- results varied between 0.0378 ± 0.0112 and 0.0432 ± 0.0095 ml/min ml with a fixed vB and 0.0408 ± 0.0111 and 0.045 ± 0.0102 ml/min ml with a free-fitted vB. The corresponding Patl- -results varied between 0.0302 ± 0.0071 and 0.0325 ± 0.0070 ml/min ml, having lesser differences and variances. The input functions with least variance and mean differences compared with NLR results were derived from the left ventricle with a VOI volume of 19.2 ± 11.3 cm corrected for PVE and Bg with a mean -difference: 0.0097 ± 0.0370 ml/min ml and 95% confidence limits (-0.023 to 0.004).

CONCLUSIONS

Our results indicated that a VOI with a volume of approximately 20 cm with a correction factor of 0.83 ± 0.13 results in Patlak results with the least variance and difference compared with the NLR results. The use of free-fitted vB in the NLR analysis showed the most robust results in all input series. The Patlak results were in comparison generally lower than the NLR results (-17.3% to -23.4%) but very robust across the various input series and with results comparable to previously published data and are therefore recommended for future analysis.

摘要

引言

本研究的目的是调查在一组慢性肾脏病 - 矿物质和骨异常(CKD - MBD)患者中,使用不同输入参数对所得骨血浆清除率( )及其他动力学建模参数的影响。

方法

使用左心室和胸主动脉中五个不同的感兴趣区(VOI)对原始PET/CT数据和血液数据进行系统分析。在四个胸椎中放置标准化VOI,并将结果汇总并平均。对基本的图像衍生输入函数(IDIF)进行部分容积效应和溢出校正,并通过用从血样中得出的相应血浆指数替代终末图像指数进行修正。然后使用非线性回归(NLR)分析和图形化Patlak分析计算 ,并进行比较。

结果

我们最初的结果具有可重复性,观察者间差异约为6%。校正因子随VOI体积而变化,从最大的左心室VOI(48.7±25.3 cm)的0.73±0.17到胸主动脉VOI(3.4±1.2 cm)的0.99±0.10。在固定vB时,平均NLR - 结果在0.0378±0.0112和0.0432±0.0095 ml/min ml之间变化,在自由拟合vB时为0.0408±0.0111和0.045±0.0102 ml/min ml。相应的Patl - 结果在0.0302±0.0071和0.0325±0.0070 ml/min ml之间变化,差异和方差较小。与NLR结果相比,方差和平均差异最小的输入函数来自左心室,VOI体积为19.2±11.3 cm,经PVE和Bg校正,平均 - 差异为:0.0097±0.0370 ml/min ml,95%置信区间为( - 0.023至0.004)。

结论

我们的结果表明,体积约为20 cm、校正因子为0.83±0.13的VOI所得到的Patlak结果与NLR结果相比,方差和差异最小。在NLR分析中使用自由拟合vB在所有输入系列中显示出最稳健的结果。相比之下,Patlak结果通常低于NLR结果( - 17.3%至 - 23.4%),但在各种输入系列中非常稳健,且结果与先前发表的数据相当,因此推荐用于未来分析。