MMWR Morb Mortal Wkly Rep. 2024 Oct 3;73(39):883-887. doi: 10.15585/mmwr.mm7339a4.
Ice machines can harbor water-related organisms, and the use of ice or tap water for clinical care activities has been associated with infections in health care settings. During 2021-2022, a total of 23 cases of infection by Burkholderia multivorans (sequence type ST659) were reported at two southern California hospitals and linked to contaminated ice and water from ice machines. In addition to these 23 cases, this report also includes 23 previously unreported cases of B. multivorans ST659 infections that occurred during 2020-2024: 13 at a northern California hospital, eight at a hospital in Colorado, and two additional cases at one of the southern California hospitals. The same brand of ice machine and brands of filters, descaling, and sanitizing products were used by all four hospitals; B. multivorans was isolated from samples collected from ice machines in two of the hospitals. Whole genome sequencing indicated that all clinical and ice machine isolates were highly genetically similar (0-14 single nucleotide variant differences across 81% of the selected reference genome). Recommendations from public health officials to halt the outbreak included avoiding ice and tap water during clinical care activities. An investigation is ongoing to determine possible sources of ice machine contamination. During outbreaks of water-related organisms in health care facilities, health care personnel should consider avoiding the use of tap water, including ice and water from ice machines, for patient care.
制冰机能藏匿与水相关的微生物,而在临床护理活动中使用冰或自来水与医疗机构感染相关。在 2021 年至 2022 年期间,加利福尼亚州南部的两家医院共报告了 23 例由伯克霍尔德氏菌(ST659 型)引起的感染病例,这些感染与制冰机污染的冰和水有关。除了这 23 例病例外,本报告还包括 2020 年至 2024 年期间发生的 23 例先前未报告的伯克霍尔德氏菌 ST659 感染病例:13 例发生在加利福尼亚州北部的一家医院,8 例发生在科罗拉多州的一家医院,另外两例发生在加利福尼亚州南部的一家医院。四家医院均使用了同一品牌的制冰机和品牌的过滤器、除垢剂和消毒剂;从两家医院的制冰机采集的样本中分离出了伯克霍尔德氏菌。全基因组测序表明,所有临床和制冰机分离株具有高度相似的遗传特征(81%的选定参考基因组中有 0-14 个单核苷酸差异)。公共卫生官员建议停止疫情爆发,包括在临床护理活动中避免使用冰和自来水。目前正在进行调查以确定制冰机污染的可能来源。在医疗机构中与水有关的微生物爆发期间,医护人员应考虑避免在患者护理中使用自来水,包括制冰机的冰和水。