Abstract

INTRODUCTION

Survey or localiser radiographs are integral to CT imaging. However, the diverse functions and roles of the localiser radiograph are often obscure to radiographers and radiologists. This scoping review reports the full scope of localiser radiograph use and function in contemporary CT imaging.

METHODS

A scoping review was performed. A systematic literature search was conducted using four databases: MEDLINE, CINAHL, Emcare and Scopus from January 2013 to December 2023. Data extraction was conducted by two review authors and validated by a third reviewer. Thirty-six studies were included in this review.

RESULTS

Three major themes emerged: radiation dose management, image quality considerations and clinical protocol applications. Specifically, the number, order of selection and directions of localiser radiographs significantly impact patient dose and image quality; which are additionally impacted by off-centre patient positioning, which can influence the accuracy of body size estimates and CT numbers. Finally, the optimal selection of localiser radiographs, including exposure parameters (kVp, mAs), can be a part of clinical task-based imaging protocol optimisation.

CONCLUSIONS

The utilities of localiser radiographs in CT imaging are varied. It is salient that radiographers and radiologists understand their role and the impacts of poor application to ensure that radiation dose is minimised and image quality maximised through correct use. Radiographers and radiologists should also be aware of the impact of poor patient positioning on ACTM function, dose and image quality. Additionally, localiser radiographs should be used for clinical task-based protocol optimisation.

IMPLICATIONS FOR PRACTICE

The number, order of selection, direction, patient off-centring, and exposure parameters must be considered when utilising localiser radiographs as they impact dose, image quality, and protocol applications. It is essential for radiographers and radiologists to understand these impacts.

摘要

简介

在 CT 成像中,扫描或定位片是不可或缺的。然而,对于放射技师和放射科医生来说,定位片的各种功能和作用往往并不清楚。本范围界定综述报告了当代 CT 成像中定位片使用和功能的全部范围。

方法

进行了范围界定综述。使用四个数据库(MEDLINE、CINAHL、Emcare 和 Scopus)进行了系统文献检索,检索时间范围为 2013 年 1 月至 2023 年 12 月。两名综述作者进行了数据提取,并由第三名综述作者进行验证。本综述共纳入 36 项研究。

结果

出现了三个主要主题:辐射剂量管理、图像质量考虑因素和临床方案应用。具体而言,定位片的数量、选择顺序和方向对患者剂量和图像质量有重大影响;患者偏离中心的位置也会影响身体大小估计和 CT 数的准确性。最后,正确选择定位片,包括曝光参数(kVp、mAs),可以是临床基于任务的成像方案优化的一部分。

结论

定位片在 CT 成像中的应用多种多样。重要的是,放射技师和放射科医生要了解其作用和应用不当的影响,以确保通过正确使用将辐射剂量降至最低并最大限度地提高图像质量。放射技师和放射科医生还应意识到患者定位不良对 ACTM 功能、剂量和图像质量的影响。此外,应根据临床任务使用定位片进行协议优化。

实践意义

在使用定位片时,必须考虑其数量、选择顺序、方向、患者偏离中心位置和曝光参数,因为它们会影响剂量、图像质量和方案应用。放射技师和放射科医生了解这些影响至关重要。