Suppr超能文献

工作长度测定中效能的比较评估:使用[具体方法]并经体视显微镜验证的X线摄影与电子根尖定位仪的比较

Comparative evaluation of efficacy in working length determination: Radiography versus Electronic apex locators using and methods with stereomicroscope validation.

作者信息

Saha Debjani, Mazumdar Dibyendu, Biswas Mousumi, Chanani Ankit, Das Snigdho

机构信息

Department of Conservative Dentistry and Endodontics, Dr. R. Ahmed Dental College and Hospital, Kolkata, West Bengal, India.

Muskan Point, Siliguri, West Bengal, India.

出版信息

J Conserv Dent Endod. 2024 Aug;27(8):790-794. doi: 10.4103/JCDE.JCDE_381_24. Epub 2024 Aug 7.

Abstract

BACKGROUND

Accurate determination of the working length (WL) is crucial for successful endodontic treatment. Various methods, including radiography and electronic apex locators (EALs), are employed for WL measurement, each with its advantages and limitations.

AIM

This study aimed to compare the accuracy of WL determination using conventional radiography and the Root ZX Mini EAL against an gold standard method.

MATERIALS AND METHODS

Fifty single-rooted teeth scheduled for extraction were included. WLs were determined using radiography (Grossman's method) and the Root ZX Mini EAL. An method served as the gold standard with WL carried out on extracted teeth under a stereomicroscope. Statistical analysis included Paired samples -test, Chi-square test, and Bland-Altman plots.

RESULTS

The mean WL values were comparable among methods, with slight variations in precision. The Root ZX Mini EAL demonstrated significantly lower mean absolute error compared to radiography ( < 0.001). Accuracy within ± 0.5 mm and ± 1 mm tolerance ranges favored the EAL over radiography ( = 0.04 and = 0.004, respectively).

CONCLUSION

The Root ZX Mini EAL exhibited superior accuracy and lower error rates in WL determination compared to radiography. Integrating EALs alongside radiographic techniques is recommended to optimize WL precision in clinical practice.

摘要

背景

准确确定工作长度(WL)对于成功的牙髓治疗至关重要。包括放射照相术和电子根尖定位仪(EALs)在内的各种方法都用于测量工作长度,每种方法都有其优点和局限性。

目的

本研究旨在将传统放射照相术和Root ZX Mini电子根尖定位仪测定工作长度的准确性与金标准方法进行比较。

材料与方法

纳入50颗计划拔除的单根牙。使用放射照相术(格罗斯曼法)和Root ZX Mini电子根尖定位仪测定工作长度。在体视显微镜下对拔除的牙齿进行工作长度测量作为金标准方法。统计分析包括配对样本t检验、卡方检验和布兰德-奥特曼图。

结果

各方法的平均工作长度值具有可比性,精度略有差异。与放射照相术相比,Root ZX Mini电子根尖定位仪的平均绝对误差显著更低(P<0.001)。在±0.5mm和±1mm公差范围内的准确性方面,电子根尖定位仪优于放射照相术(分别为P = 0.04和P = 0.004)。

结论

与放射照相术相比,Root ZX Mini电子根尖定位仪在测定工作长度时表现出更高的准确性和更低的误差率。建议在临床实践中将电子根尖定位仪与放射照相技术结合使用,以优化工作长度的精度。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/7bf2/11451680/585cac924d08/JCDE-27-790-g001.jpg

相似文献

2
Accuracy of Working Length Determination using NovApex and Root-ZX Apex Locators: An in vitro Study.
J Contemp Dent Pract. 2017 May 1;18(5):383-385. doi: 10.5005/jp-journals-10024-2051.
3
Comparative evaluation of working length determined using integrated apex locator and root ZX mini under various irrigating solutions: An study.
J Conserv Dent Endod. 2023 Sep-Oct;26(5):590-594. doi: 10.4103/JCDE.JCDE_68_23. Epub 2023 Sep 16.
6
Efficiency of 2 electronic apex locators on working length determination: A clinical study.
J Conserv Dent. 2013 May;16(3):229-32. doi: 10.4103/0972-0707.111320.
7
Comparative evaluation of root ZX Mini® apex locator and radiovisiography in determining the working length of primary molars: An In Vivo study.
J Oral Biol Craniofac Res. 2021 Apr-Jun;11(2):257-262. doi: 10.1016/j.jobcr.2021.02.007. Epub 2021 Feb 17.
8
In vivo evaluation of the iPex and Root ZX electronic apex locators using various irrigants.
Int Endod J. 2013 Aug;46(8):769-74. doi: 10.1111/iej.12057. Epub 2013 Mar 28.
9
Comparative evaluation of accuracy of 2 electronic Apex locators with conventional radiography: an ex vivo study.
J Endod. 2015 Feb;41(2):201-4. doi: 10.1016/j.joen.2014.10.011. Epub 2014 Dec 2.
10
An in vitro evaluation of the accuracy of four electronic apex locators using stainless-steel and nickel-titanium hand files.
Restor Dent Endod. 2016 Feb;41(1):6-11. doi: 10.5395/rde.2016.41.1.6. Epub 2016 Jan 4.

本文引用的文献

1
Accuracy of the electronic apex locator, tactile, and radiographic methods in working length determination.
J Conserv Dent. 2023 May-Jun;26(3):311-315. doi: 10.4103/jcd.jcd_45_23. Epub 2023 May 16.
6
Accuracy and repeatability of 3 apex locators in locating root canal perforations: an ex vivo study.
J Endod. 2014 Aug;40(8):1241-4. doi: 10.1016/j.joen.2014.02.004. Epub 2014 Apr 21.
7
Accuracy of three electronic apex locators in anterior and posterior teeth: an ex vivo study.
J Endod. 2011 May;37(5):684-7. doi: 10.1016/j.joen.2011.02.011. Epub 2011 Mar 22.
8
Accuracy of three electronic apex locators compared with digital radiography: an ex vivo study.
J Endod. 2010 Dec;36(12):2003-7. doi: 10.1016/j.joen.2010.08.036.
10
Consistency of apex locator function: a clinical study.
J Endod. 2009 Feb;35(2):179-81. doi: 10.1016/j.joen.2008.10.017. Epub 2008 Dec 12.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验