潮气量为6和10 ml/kg的两种通气方法中动态顺应性与静态顺应性的比较:随机临床试验

Comparison of Dynamic and Static Compliance in Two Ventilation Methods with Tidal Volume of 6 and 10 ml/kg: Randomized Clinical Trial.

作者信息

Taghavi Gilani Mehryar, Bameshki Alireza, Razavi Majid, Sadeghzadeh Ghorbanali

机构信息

Lung Disease Research Center, Department of Anesthesiology, Mashhad University of Medicine Sciences, Mashhad, Iran.

出版信息

Med J Islam Repub Iran. 2024 Jun 26;38:73. doi: 10.47176/mjiri.38.73. eCollection 2024.

Abstract

BACKGROUND

Pulmonary compliance is an important lung factor and is affected by tidal volume. In this study, static and dynamic compliance with tidal volumes of 6 and 10 ml/kg have been evaluated in patients undergoing abdominal cancer surgery.

METHODS

This randomized clinical trial was conducted on 50 patients who were candidate for abdominal cancer surgery. This study was done in patients aged 20-65 years without chronic diseases. After induction of anesthesia, the first group was ventilated with a tidal volume of 10 ml/kg and 8 breaths/minute, and also the second group was ventilated with a tidal volume of 6 mL/kg and 14 breaths/minute. From the beginning and every 15 minutes, expiratory tidal volume, peak and plateau airway pressure, heart rate and blood pressure were measured for two hours. The data was analyzed with SPSS v.20 and < 0.05 was meaningful.

RESULTS

There was no significant difference between the two groups for demographic characteristics. There was no significant difference between the two groups in the dynamic and static compliance of the patients during the study. However, the static compliance decreased in the 6 ml/kg group and increased in the 10 ml/kg group, but the difference was not statistically significant ( = 0.32). The peak, plateau pressure and hemodynamic parameters were the same in the two groups.

CONCLUSION

In general, the static and dynamic compliance was not significantly different in the two groups despite a slight decrease in the 6 ml/kg group and a slight increase in the 10 ml/kg group.

摘要

背景

肺顺应性是一项重要的肺部指标,且受潮气量影响。在本研究中,对接受腹部癌症手术的患者评估了6 ml/kg和10 ml/kg潮气量下的静态和动态顺应性。

方法

本随机临床试验对50例腹部癌症手术候选患者进行。该研究纳入年龄在20 - 65岁且无慢性疾病的患者。麻醉诱导后,第一组以10 ml/kg潮气量和8次/分钟的呼吸频率进行通气,第二组以6 ml/kg潮气量和14次/分钟的呼吸频率进行通气。从开始及每隔15分钟,测量呼气潮气量、气道峰压和平台压、心率及血压,持续两小时。数据采用SPSS v.20进行分析,P < 0.05具有统计学意义。

结果

两组患者的人口统计学特征无显著差异。研究期间两组患者的动态和静态顺应性无显著差异。然而,6 ml/kg组的静态顺应性降低,10 ml/kg组的静态顺应性升高,但差异无统计学意义(P = 0.32)。两组的气道峰压、平台压及血流动力学参数相同。

结论

总体而言,尽管6 ml/kg组略有下降,10 ml/kg组略有上升,但两组的静态和动态顺应性无显著差异。