Departments of Ophthalmology, Biochemistry & Molecular Biology, and Pharmacology & Toxicology, Eugene and Marilyn Glick Eye Institute, Stark Neurosciences Research Institute, Indiana University School of Medicine, Indianapolis, IN, USA.
Methods Mol Biol. 2025;2858:113-122. doi: 10.1007/978-1-0716-4140-8_10.
Human anterior segment perfusion cultures are frequently used for trabecular meshwork research. However, this model requires the use of whole eye globes which are expensive. Here, we describe a method using human corneal rims as an alternative to anterior segments for perfusion culture. In this method, the human corneal rim is glued to a three-dimensional-printed perfusion plates instead of using mechanical compression in traditional perfusion culture setup. The corneal rim and perfusion plate are placed onto a special holder for perfusion culture. This method is affordable and easy to set up. The instruments for traditional perfusion culture studies can be used for this model without modification.
人眼前段灌注培养常用于小梁网研究。然而,这种模型需要使用整个眼球,这是昂贵的。在这里,我们描述了一种使用人眼角膜缘作为灌注培养替代前节的方法。在这种方法中,人眼角膜缘被粘在三维打印的灌注板上,而不是在传统的灌注培养设置中使用机械压缩。角膜缘和灌注板被放置在一个特殊的灌注培养支架上。这种方法经济实惠,易于设置。传统的灌注培养研究仪器可以在不修改的情况下用于该模型。