Suppr超能文献

基于相干估计器的三相同步电机输出扰动与不平衡智能检测及评估方案的实验性能验证

Experimental performance verification of an intelligent detection and assessment scheme for disturbances and imbalances of three-phase synchronous machine output using coherence estimators.

作者信息

Mahmoud R A

机构信息

Misr University for Science and Technology (MUST), College of Engineering Science & Technology, Department of Electrical Power and Machines Engineering (PME), 6Th of October City, Giza, Egypt.

出版信息

Sci Rep. 2024 Nov 1;14(1):26278. doi: 10.1038/s41598-024-76343-8.

Abstract

In this article, power quality disturbances, such as voltage and current unbalances, series and shunt faults, are monitored in three-phase synchronous machines. Because the imbalances affect machine efficiency and service life, it is essential to figure out whether the three-phase voltages/currents are balanced or unbalanced. An integrated detection algorithm is proposed to detect the unbalanced voltages/currents and various abnormal conditions precisely and quickly, which is based on the coherence estimator. Most existing detection methods require more than one cycle time to determine the contingency conditions, while the proposed technique detects these situations in a fast and discrete protection system. The suggested scheme acquires instantaneous measurements of the three-phase voltages and currents taken at the synchronous machine terminals in order to calculate fifteen coherence coefficients that are utilized to detect and assess any unbalance or trouble accurately and swiftly. A new proposal for imbalance and disturbance indicators based on the coherence estimators is developed in this study. Multiple test cases have been conducted to validate the proposed algorithm capabilities using a real power system, which includes a motor-generator set, a three-phase load and measurement transformers. The experimental results have been revealed that the relay reliability and accuracy percentages have been found to be 98.28% and 98.52%, respectively. The quantitative findings of the imbalance and disturbance assessment are recorded.

摘要

在本文中,对三相同步电机中的电能质量扰动进行监测,如电压和电流不平衡、串联和并联故障。由于这些不平衡会影响电机效率和使用寿命,因此确定三相电压/电流是平衡还是不平衡至关重要。提出了一种基于相干估计器的综合检测算法,用于精确快速地检测不平衡电压/电流及各种异常情况。大多数现有检测方法需要一个多周期时间来确定故障情况,而所提出的技术能在快速离散保护系统中检测这些情况。该方案获取同步电机端子处三相电压和电流的瞬时测量值,以计算15个相干系数,用于准确快速地检测和评估任何不平衡或故障。本研究提出了一种基于相干估计器的不平衡和扰动指标新方案。使用包括电动发电机组、三相负载和测量变压器的实际电力系统进行了多个测试案例,以验证所提算法的能力。实验结果表明,继电器的可靠性和准确率分别为98.28%和98.52%。记录了不平衡和扰动评估的定量结果。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/ba75/11530546/c126add3a3ff/41598_2024_76343_Fig1a_HTML.jpg