Suppr超能文献

飞行时间法改进:开发一种使用智能手机应用程序测量垂直跳跃高度的新颖且更精确的方法。

Flight-Time Method Modified: Development of a Novel and More Accurate Method for Measuring Vertical Jump Height Using a Smartphone Application.

作者信息

Nishioka Takuya, Yamaguchi Shota, Inami Takayuki

机构信息

Institute of Physical Education, Keio University, Yokohama, Japan.

出版信息

Int J Sports Physiol Perform. 2024 Nov 5;20(1):56-64. doi: 10.1123/ijspp.2024-0063. Print 2025 Jan 1.

Abstract

PURPOSE

The flight-time method (FT) is used for measuring vertical jump height (JH) in the field because of its convenience; however, FT overestimates JH when the lower limb is flexed at landing. Herein, we proposed a new method (ie, flight-time method modified [FTM]) to address the problem of FT and evaluate its validity and reliability.

METHODS

A total of 24 men performed 6 countermovement jumps on force plates (sampling rate: 1000 Hz) while being recorded with a smartphone high-speed camera at 240 frames·s-1. JH was calculated by the impulse-momentum method (IM), FT, and FTM. For FTM, the flight time and JH were calculated based on the displacement of the greater-trochanter marker using a smartphone application.

RESULTS

JH calculated using FT was significantly higher (P < .001) compared with JH calculated by IM; however, JH calculated by FTM showed no significant difference with JH calculated by IM. Furthermore, JH calculated by FTM, compared with JH calculated by FT (ρ = .882; 95% CI, .838-.914), exhibited a stronger, nearly perfect, and significantly positive correlation (ρ = .987; 95% CI, .982-.991) with JH calculated by IM and showed high reliability.

CONCLUSIONS

The FTM proposed in this study had higher concurrent validity compared with FT and a high reliability for measuring countermovement JH because it was not affected by lower-extremity flexion at landing. Therefore, practitioners should consider using FTM as a convenient, low-cost, reliable, and more valid method for measuring JH in the field.

摘要

目的

飞行时间法(FT)因其便捷性而被用于现场测量垂直跳跃高度(JH);然而,当下肢在着地时弯曲时,FT会高估JH。在此,我们提出一种新方法(即改良飞行时间法[FTM])来解决FT的问题,并评估其有效性和可靠性。

方法

24名男性在测力板上进行6次反向纵跳(采样率:1000Hz),同时用智能手机高速摄像机以240帧·秒⁻¹的速度进行记录。JH通过冲量-动量法(IM)、FT和FTM进行计算。对于FTM,使用智能手机应用程序根据大转子标记的位移计算飞行时间和JH。

结果

与通过IM计算的JH相比,使用FT计算的JH显著更高(P <.001);然而,通过FTM计算的JH与通过IM计算的JH没有显著差异。此外,与通过FT计算的JH相比(ρ =.882;95%CI,.838-.914),通过FTM计算的JH与通过IM计算的JH表现出更强、近乎完美且显著的正相关(ρ =.987;95%CI,.982-.991),并显示出高可靠性。

结论

本研究中提出的FTM与FT相比具有更高的同时效度,并且在测量反向纵跳JH方面具有高可靠性,因为它不受着地时下肢弯曲的影响。因此,从业者应考虑将FTM作为一种方便、低成本、可靠且更有效的现场测量JH的方法。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验