三种用于脊柱手术的 3D 移动 X 射线成像引导设备的图像质量比较:一项体模研究。

Image Quality Comparison of Three 3D Mobile X-Ray Imaging Guidance Devices Used in Spine Surgery: A Phantom Study.

机构信息

Department of Medical Imaging, IMAGINE UR UM 103, Montpellier University, Nimes University Hospital, Bd Prof Robert Debré, CEDEX 9, 30029 Nîmes, France.

Medical Physics and Radiation Protection Department, APHP Lariboisière University Hospital, 75010 Paris, France.

出版信息

Sensors (Basel). 2024 Oct 26;24(21):6883. doi: 10.3390/s24216883.


DOI:10.3390/s24216883
PMID:39517780
原文链接:https://pmc.ncbi.nlm.nih.gov/articles/PMC11548279/
Abstract

An image-quality CT phantom was scanned with three different 3D X-ray imaging guidance devices in the operating theatre: O-Arm, Loop-X, and Airo TruCT. Default acquisition and reconstruction parameters for lumbar spine procedures were used on each device. The tube current was set to a dose level of around 27 mGy. A task-based image quality assessment was performed by calculating the noise power spectrum (NPS) and task transfer function (TTF). A detectability index (d') was calculated for three simulated bone lesions. The noise magnitude of the O-Arm was higher than the Airo TruCT, and the Loop-X had higher noise than the Airo TruCT. The highest average NPS frequency was for the O-Arm images, and the lowest was for the Loop-X. The TTFs at 50% values were similar for the Airo TruCT and Loop-X devices. Compared to Airo TruCT, the TTF at 50% value increased with the O-Arm by 53.12% and 41.20% for the Teflon and Delrin inserts, respectively. Compared to Airo TruCT, the d' value was lower with Loop-X by -26.73%, -27.02%, and -23.95% for lytic lesions, sclerotic lesions, and high-density bone, respectively. Each 3D-imaging spine surgery guidance device has its own strengths and weaknesses in terms of image quality. Cone-beam CT systems apparently offer the best compromise between noise and spatial resolution for spine surgery.

摘要

在手术室中,使用三种不同的 3D X 射线成像引导设备对一个图像质量 CT 体模进行了扫描:O-Arm、Loop-X 和 Airo TruCT。每种设备都使用了腰椎程序的默认采集和重建参数。管电流设置为约 27 mGy 的剂量水平。通过计算噪声功率谱(NPS)和任务传递函数(TTF)进行了基于任务的图像质量评估。为三个模拟骨病变计算了检测指数(d')。O-Arm 的噪声幅度高于 Airo TruCT,而 Loop-X 的噪声高于 Airo TruCT。O-Arm 图像的平均 NPS 频率最高,Loop-X 最低。Airo TruCT 和 Loop-X 设备的 TTF 在 50%值处相似。与 Airo TruCT 相比,O-Arm 的 TTF 在 50%值处增加了 53.12%和 41.20%,用于 Teflon 和 Delrin 插件。与 Airo TruCT 相比,Loop-X 的 d'值分别降低了 -26.73%、-27.02%和 -23.95%,用于溶骨性病变、硬化性病变和高密度骨。每种用于脊柱手术的 3D 成像引导设备在图像质量方面都有其自身的优势和劣势。锥形束 CT 系统显然在脊柱手术的噪声和空间分辨率之间提供了最佳折衷。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/0e17/11548279/618110fb28a8/sensors-24-06883-g004.jpg
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/0e17/11548279/d433f27c8f3a/sensors-24-06883-g001.jpg
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/0e17/11548279/0f86dc1ecf68/sensors-24-06883-g002.jpg
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/0e17/11548279/63fa1f8df49e/sensors-24-06883-g003.jpg
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/0e17/11548279/618110fb28a8/sensors-24-06883-g004.jpg
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/0e17/11548279/d433f27c8f3a/sensors-24-06883-g001.jpg
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/0e17/11548279/0f86dc1ecf68/sensors-24-06883-g002.jpg
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/0e17/11548279/63fa1f8df49e/sensors-24-06883-g003.jpg
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/0e17/11548279/618110fb28a8/sensors-24-06883-g004.jpg

相似文献

[1]
Image Quality Comparison of Three 3D Mobile X-Ray Imaging Guidance Devices Used in Spine Surgery: A Phantom Study.

Sensors (Basel). 2024-10-26

[2]
Image Quality and Dose Comparison of 3 Mobile Intraoperative Three-Dimensional Imaging Systems in Spine Surgery.

World Neurosurg. 2022-4

[3]
Mobile C-arm cone-beam CT for guidance of spine surgery: image quality, radiation dose, and integration with interventional guidance.

Med Phys. 2011-8

[4]
Optimization of radiation dose for CT detection of lytic and sclerotic bone lesions: a phantom study.

Eur Radiol. 2019-9-10

[5]
Effective dose and image quality for intraoperative imaging with a cone-beam CT and a mobile multi-slice CT in spinal surgery: A phantom study.

Phys Med. 2021-1

[6]
Radiation dose and image quality comparison during spine surgery with two different, intraoperative 3D imaging navigation systems.

J Appl Clin Med Phys. 2019-2

[7]
Improved image quality and dose reduction in abdominal CT with deep-learning reconstruction algorithm: a phantom study.

Eur Radiol. 2023-1

[8]
Super-resolution deep-learning reconstruction for cardiac CT: impact of radiation dose and focal spot size on task-based image quality.

Phys Eng Sci Med. 2024-9

[9]
A systematic task-based image quality assessment of photon-counting and energy integrating CT as a function of reconstruction kernel and phantom size.

Med Phys. 2024-2

[10]
Use of the Airo mobile intraoperative CT system versus the O-arm for transpedicular screw fixation in the thoracic and lumbar spine: a retrospective cohort study of 263 patients.

J Neurosurg Spine. 2018-10

本文引用的文献

[1]
The use of intraoperative CT-neuronavigation in Wiltse approach. A technical note.

Front Surg. 2024-9-2

[2]
Task-based image quality assessment of an intraoperative CBCT for spine surgery compared with conventional CT.

Phys Med. 2024-8

[3]
Radiation doses and accuracy of navigated pedicle screw placement in cervical and thoracic spine surgery: a comparison of sliding gantry CT and mobile cone-beam CT in a homogeneous cohort.

J Neurosurg Spine. 2023-9-1

[4]
Intraoperative mobile computed tomography in deep brain stimulation: Comparison between Airo CT and O-arm CT.

Surg Neurol Int. 2022-6-17

[5]
iQMetrix-CT: New software for task-based image quality assessment of phantom CT images.

Diagn Interv Imaging. 2022-11

[6]
Fluoroscopic imaging: New advances.

Injury. 2022-11

[7]
Image Quality and Dose Comparison of 3 Mobile Intraoperative Three-Dimensional Imaging Systems in Spine Surgery.

World Neurosurg. 2022-4

[8]
Comparison of Supervised and Unsupervised Approaches for the Generation of Synthetic CT from Cone-Beam CT.

Diagnostics (Basel). 2021-8-9

[9]
Mobile intraoperative CT-assisted frameless stereotactic biopsies achieved single-millimeter trajectory accuracy for deep-seated brain lesions in a sample of 7 patients.

BMC Neurol. 2021-7-22

[10]
Intraoperative image guidance for cervical spine surgery.

Ann Transl Med. 2021-1