Suppr超能文献

Trueness and adaptation of screw-retained implant-supported monolithic zirconia crowns fabricated using 3-dimensional gel deposition.

作者信息

Sun Zhe, Li Yuan, Zhao Jing, Zheng Yuanna

机构信息

Attending physician, School/Hospital of Stomatology, Zhejiang Chinese Medical University, Hangzhou, PR China.

Practicing physician, Department of Stomatology, The Third People's Hospital of Changzhou, Changzhou, PR China.

出版信息

J Prosthet Dent. 2025 Jan;133(1):229.e1-229.e7. doi: 10.1016/j.prosdent.2024.10.005. Epub 2024 Nov 12.

Abstract

STATEMENT OF PROBLEM

Implant-supported monolithic zirconia restorations manufactured using the additive 3-dimensional (3D) gel deposition technique have been introduced. However, studies determining the trueness and adaptation of implant-supported crowns made with the technique are lacking.

PURPOSE

The purpose of this in vitro study was to evaluate the trueness and adaptation of implant-supported zirconia crowns fabricated using additive 3D gel deposition in comparison with zirconia crowns made with the widely used subtractive milling technique.

MATERIAL AND METHODS

Crowns were fabricated for wide-diameter titanium implants and wide-neck abutments. Self-glazed zirconia (SGZ) crowns were fabricated using 3D gel deposition (n=10) and from 2 brands of zirconia blanks, Wieland and Upcera, using subtractive milling (WMZ and UMZ, n=10). All crowns were digitalized by a scanner, and then 3D deviation analysis was applied. The trueness was assessed by root mean square (RMS). Marginal and internal adaptations were evaluated using the direct-view technique (DT) and replica technique (RT). The results were analyzed by using the 1-way ANOVA and Kruskal-Wallis statistical tests (α=.05).

RESULTS

The RMS and marginal discrepancy of SGZ exhibited the lowest values among the 3 groups (P<.05), and the 2 types of milled zirconia crowns had comparable RMS and marginal discrepancy values (P>.05). The internal discrepancy values of SGZ were significantly lower than those of WMZ and UMZ in all regions (P<.05). Compared with the WMZ, UMZ showed comparable internal discrepancy values in the axial and axio-occlusal transition regions (P>.05) but had significantly lower internal discrepancy value in the occlusal region (P<.05).

CONCLUSIONS

The adaptation of 3 types of wide-diameter implant-supported zirconia crowns can meet the clinical requirements. Compared with the subtractive milling process, 3D gel deposition produced implant-supported zirconia crowns with improved trueness and adaptation.

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验