Huang Bangyan, Qi Jinyi
Department of Biomedical Engineering, University of California, Davis, Davis, CA, United States of America.
Phys Med Biol. 2024 Dec 4;69(24). doi: 10.1088/1361-6560/ad9543.
Positronium lifetime tomography (PLT) is an emerging modality that aims to reconstruct 3D images of positronium lifetime in humans and animals. The lifetime of ortho-positronium can be influenced by the microstructure and the concentration of bio-active molecules in tissue, providing valuable information for better understanding disease progression and treatment response. However, efficient high-resolution lifetime image reconstruction methods are currently lacking. Existing methods are either computationally intensive or have poor spatial resolution. This paper presents a fast, high-resolution lifetime image reconstruction method for PLT.. The proposed method, called SIMPLE-Moment (Statistical IMage reconstruction of Positron annihilation LifetimE by Moment weighting), first reconstructs a set of moment images and then estimates the ortho-positronium lifetime image using the method of moments. The implementation of SIMPLE-Moment requires minimal modification to the conventional ordered subset expectation maximization algorithm.With reasonable assumptions, the proposed method can reconstruct an ortho-positronium lifetime image with a computational cost equivalent to three standard positron emission tomography (PET) image reconstructions. A Monte Carlo simulation study based on an existing time-of-flight PET scanner demonstrates that the ortho-positronium lifetime image reconstructed by SIMPLE-Moment is accurate and comparable to results obtained using the more computationally intensive Statistical Positronium Lifetime Image reconstruction via time-Thresholding (SPLIT) method.. The proposed SIMPLE-Moment method provides an efficient approach to high-resolution reconstruction of ortho-positronium lifetime images. By reducing computational costs while enhancing spatial resolution, this method has the potential to make PLT more accessible and practical for clinical and research applications.
正电子素寿命断层扫描(PLT)是一种新兴的成像方式,旨在重建人体和动物体内正电子素寿命的三维图像。仲正电子素的寿命会受到组织中生物活性分子的微观结构和浓度的影响,为更好地理解疾病进展和治疗反应提供有价值的信息。然而,目前缺乏高效的高分辨率寿命图像重建方法。现有方法要么计算量大,要么空间分辨率差。本文提出了一种用于PLT的快速、高分辨率寿命图像重建方法。所提出的方法称为SIMPLE-Moment(通过矩加权对正电子湮没寿命进行统计图像重建),首先重建一组矩图像,然后使用矩量法估计仲正电子素寿命图像。SIMPLE-Moment的实现只需对传统的有序子集期望最大化算法进行最小程度的修改。在合理的假设下,所提出的方法可以重建仲正电子素寿命图像,其计算成本相当于三次标准正电子发射断层扫描(PET)图像重建。基于现有的飞行时间PET扫描仪进行的蒙特卡罗模拟研究表明,通过SIMPLE-Moment重建的仲正电子素寿命图像是准确的,并且与使用计算量更大的通过时间阈值化进行统计正电子素寿命图像重建(SPLIT)方法获得的结果相当。所提出的SIMPLE-Moment方法为仲正电子素寿命图像的高分辨率重建提供了一种有效的方法。通过降低计算成本同时提高空间分辨率,该方法有可能使PLT在临床和研究应用中更易于使用和实用。