Suppr超能文献

使用计算机断层扫描以亨氏单位评估骨质量:应采用什么值来将骨分类为正常或骨质疏松?

Assessing bone quality in hounsfield units using computed tomography: what value should be used to classify bone as normal or osteoporotic?

作者信息

Courtois Emily C, Ohnmeiss Donna D

机构信息

Texas Back Institute, Plano, Texas, USA.

Texas Back Institute Research Foundation, 6020 W Parker Rd., Suite 200, Plano, Texas, 75093, USA.

出版信息

Eur Spine J. 2025 Feb;34(2):493-497. doi: 10.1007/s00586-024-08565-3. Epub 2024 Nov 22.

Abstract

PURPOSE

The purpose of this study was to investigate threshold values for classifying bone as normal or osteoporotic based on Computed Tomography (CT) Hounsfield Units (HU) and to determine if clinically applicable values could be derived to aid spine surgeons evaluating bone quality using CT.

METHODS

This literature review was completed using PubMed and Ovid (MedLine), using syntax specific to bone quality and CT. The included articles were original clinical studies assessing bone quality and utilized composite L1-L4 HU values compared against dual-energy X-ray absorptiometry (DEXA) values. Extracted data study descriptors, CT measurement technique, and CT threshold values. CTs were measured from L1-L4 using either axial or sagittal images, and must classify their bone quality findings for any of the following 3 categories: normal, osteopenia, or osteoporosis.

RESULTS

This review located 34 studies measuring bone density using CT with threshold values, of which, 10 were included in the final review. Number of patients ranged from 74 to 283 and cohort ages from 20s to 70.6 years. CT threshold values for assessing normal and osteoporotic bone quality ranged from 150 to 179 and 87 to 155, respectively. From combining values across studies, a HU value of ≥ 170 HU was associated with normal bone and ≤ 115 HU with osteoporosis.

CONCLUSION

There is variation in HU values used to differentiate normal from compromised bone quality, even after limiting studies. For patients with HU values between or near 170 or 115 HU, a DEXA scan may be warranted for further evaluation. With ongoing investigation in this area, threshold values for classifying bone quality using CT will be continually refined.

摘要

目的

本研究旨在基于计算机断层扫描(CT)的亨氏单位(HU)确定将骨骼分类为正常或骨质疏松的阈值,并确定是否可以得出临床适用值,以帮助脊柱外科医生利用CT评估骨质。

方法

本综述使用PubMed和Ovid(医学在线数据库)完成,采用特定于骨质和CT的语法。纳入的文章为评估骨质的原始临床研究,并利用L1-L4椎体的综合HU值与双能X线吸收法(DEXA)值进行比较。提取的数据包括研究描述、CT测量技术和CT阈值。使用轴向或矢状面图像测量L1-L4椎体的CT值,且必须将其骨质结果分类为以下3类中的任何一类:正常、骨质减少或骨质疏松。

结果

本综述检索到34项使用CT阈值测量骨密度的研究,其中10项纳入最终综述。患者人数从74人到283人不等,队列年龄从20多岁到70.6岁。评估正常和骨质疏松骨质的CT阈值分别为150至179和87至155。综合各项研究的值,HU值≥170 HU与正常骨骼相关,≤115 HU与骨质疏松相关。

结论

即使在限制研究后,用于区分正常与受损骨质的HU值仍存在差异。对于HU值在170或115 HU之间或附近的患者,可能需要进行DEXA扫描以进一步评估。随着该领域研究的不断深入,使用CT分类骨质的阈值将不断完善。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验