Suppr超能文献

隐匿性经眶颅内穿透伤

Occult transorbital intracranial penetrating injuries.

作者信息

Mono J, Hollenberg R D, Harvey J T

出版信息

Ann Emerg Med. 1986 May;15(5):589-91. doi: 10.1016/s0196-0644(86)80998-2.

Abstract

Emergency physicians who are confronted with orbital injuries must recognize that the transorbital route offers little resistance to intracranial penetration. Neither direct inspection of an orbital wound nor plain radiographs are sufficient to evaluate the extent of penetration beyond the orbital confines. A high index of suspicion is critical to the proper assessment and subsequent management of such injuries. We present two cases of penetrating injury. In the first, an arrow caused a hematoma in the superior cerebellar peduncle after passing through the medial orbit and superior orbital fissure. In the second, a wire entered the upper lid, fractured the orbital roof, and caused a frontal hematoma.

摘要

面对眼眶损伤的急诊医生必须认识到,经眼眶途径对颅内穿透几乎没有阻力。对眼眶伤口进行直接检查或普通X线片都不足以评估超出眼眶范围的穿透程度。高度的怀疑指数对于此类损伤的正确评估和后续处理至关重要。我们报告两例穿透伤病例。第一例中,一支箭穿过内侧眼眶和眶上裂后导致小脑上脚血肿。第二例中,一根铁丝进入上眼睑,造成眶顶骨折,并导致额部血肿。