Gürler Kübra, Yilmaz Sehnaz, Dumani Aysin, Yoldas Oguz
Faculty of Dentistry, Department of Endodontics, Cukurova University, Adana, 01330, Turkey.
BMC Oral Health. 2024 Dec 5;24(1):1482. doi: 10.1186/s12903-024-05287-2.
Nickel titanium (NiTi) rotary files have drastically altered the treatment protocol in endodontics, allowing for faster and easier preparation and more thorough irrigation of the root canal system. Despite the advantages of the NiTi files, instrument separation still remains a major concern. The aim of this study was to compare the cyclic fatigue resistance of three different single-file NiTi systems after clinical use: WaveOne Gold (WOG, Dentsply Maillefer, Ballaigues, Switzerland), One Curve (OC, Micro Mega, Besancon, France), and Reciproc Blue (RPC Blue, VDW, Munich, Germany).
A total of 120 patients requiring endodontic treatment to first or second mandibular molars, were randomly divided into three groups (patient n = 40) and root canals were prepared with WOG, OC or RPC Blue. Each group consists of 2 subgroups: first use (file n = 10, patient n = 10) and third use of file (file n = 10, patient n = 30). In control group, files were subjected to cyclic fatigue test without use (file n = 10). Cyclic fatigue resistance of files was assessed by groove method. The data was evaluated by two-way ANOVA, Games & Howell post hoc and Weibull reliability analyses (p < .05).
RPC Blue files showed the highest failure time value in all groups. In third use group, OC and RPC Blue files showed significantly higher failure time values compared to WOG files (p < .05). In general, RPC Blue files show the highest values in terms of number of cycles to fracture (NCF) in all groups, while OC and WOG files follow RPC Blue files respectively. There was statistically significant difference among groups considering the fragment length (p < .05).
Within the limitations of this study, RPC Blue files exhibited highest cyclic fatigue resistance after clinical use.
镍钛(NiTi)旋转锉极大地改变了牙髓病学的治疗方案,使根管系统的预备更快、更容易,冲洗更彻底。尽管NiTi锉具有诸多优点,但器械分离仍是一个主要问题。本研究的目的是比较三种不同的单支NiTi系统在临床使用后的循环疲劳抗力:WaveOne Gold(WOG,登士柏马利费,瑞士巴拉格)、One Curve(OC,Micro Mega,法国贝桑松)和Reciproc Blue(RPC Blue,VDW,德国慕尼黑)。
总共120例需要对下颌第一或第二磨牙进行牙髓治疗的患者被随机分为三组(每组n = 40例患者),并分别用WOG、OC或RPC Blue预备根管。每组由两个亚组组成:首次使用(锉n = 10,患者n = 10)和锉的第三次使用(锉n = 10,患者n = 30)。在对照组中,锉未使用即进行循环疲劳测试(锉n = 1)。通过凹槽法评估锉的循环疲劳抗力。数据采用双向方差分析、Games & Howell事后检验和威布尔可靠性分析进行评估(p < 0.05)。
RPC Blue锉在所有组中均显示出最高的失效时间值。在第三次使用组中,OC和RPC Blue锉的失效时间值显著高于WOG锉(p < 0.05)。总体而言,RPC Blue锉在所有组中的断裂循环次数(NCF)方面显示出最高值, 而OC和WOG锉分别次之。考虑到碎片长度,各组之间存在统计学显著差异(p < 0.05)。
在本研究的局限性内,RPC Blue锉在临床使用后表现出最高的循环疲劳抗力。