Hartmann Louis, Passin Verena, Dürndorfer Sophie
Private Practice, Dresden, Germany.
J Orofac Orthop. 2024 Dec 6. doi: 10.1007/s00056-024-00563-w.
Advancements in computer-aided design and manufacturing (CAD/CAM), such as intraoral scanners, digital treatment planning, and 3D printers, offer digital alternatives to conventional orthodontics. For transforming digital data into a traditional model, precise 3D printing technologies are necessary. With numerous settings available on each 3D printer, selecting the most precise one is challenging. Therefore, the impact of layer height, printing temperature, print speed, and infill density on the accuracy of dental models was analyzed in this study.
A 3D file of a right upper central incisor was designed and printed 275 times in total with different settings for temperature, layer height, print speed, and infill density by using polylactic acid (PLA) filament on an industrial 3D printer. After scanning the models, root mean square error was calculated for analysis of precision. For each group, R value was calculated and linear regression as well as an ANOVA was performed for the factors influencing accuracy.
Printing temperature as well as layer height had statistically significant impacts on printing 3D tooth models (p < 0.05). R values of 0.43 for printing temperature as well as of 0.11 for layer height were detected. The infill density as well as the print speed had no statistically significant impacts on accuracy (p > 0.05).
This study confirms that choosing the correct printing temperature and layer height for printing dental models with PLA is important for obtaining good accuracy, whereas print speed and infill density have less of an impact.
计算机辅助设计与制造(CAD/CAM)技术的进步,如口内扫描仪、数字化治疗计划和3D打印机,为传统正畸学提供了数字化替代方案。为了将数字数据转换为传统模型,精确的3D打印技术必不可少。每台3D打印机都有众多设置选项,选择最精确的设置具有挑战性。因此,本研究分析了层高、打印温度、打印速度和填充密度对牙科模型精度的影响。
设计了右上中切牙的3D文件,并在工业3D打印机上使用聚乳酸(PLA)细丝,以不同的温度、层高、打印速度和填充密度设置总共打印275次。扫描模型后,计算均方根误差以分析精度。对每组计算R值,并对影响精度的因素进行线性回归和方差分析。
打印温度和层高对3D牙齿模型的打印有统计学显著影响(p < 0.05)。检测到打印温度的R值为0.43,层高的R值为0.11。填充密度和打印速度对精度无统计学显著影响(p > 0.05)。
本研究证实,使用PLA打印牙科模型时,选择正确的打印温度和层高对于获得良好的精度很重要,而打印速度和填充密度的影响较小。