Le Ba Thien, Even Alexia, Welniarz Antoine, Kastler Emmanuel Chartier, Denys Pierre, Joussain Charles
Faculty of Medicine of Tours, Tours, France.
Neuro-Urology Unit, Department of Physical Medecine and Rehabilitation, Raymond Poincaré Hospital (APHP), UVSQ Paris, Saclay, UMR 1179, France.
World J Urol. 2024 Dec 12;43(1):27. doi: 10.1007/s00345-024-05387-2.
The artificial urinary sphincter (AUS) remains the gold standard to treat stress urinary incontinence related to sphincter insufficiency in patients with neurogenic lower urinary tract dysfunction (NLUTD). This study aims to assess the incidence of de novo neurogenic detrusor overactivity or low bladder compliance after AUS implantation in adult spinal cord injured patients.
Retrospective observational study, descriptive by analysis of the medical records of patients followed in a department of Neuro-Urology from January 01, 2003 to March 31, 2023. The procedures followed were in accordance with the regulations of the Clinical Research and Ethics Committee and the Declaration of Helsinki of the World Medical Association.
Thirty-nine patients with spinal cord lesion were included. The incidence of de novo low bladder compliance or neurogenic detrusor overactivity with high pressure (≥ 40 cmHO) was 48.72% with a median onset delay of 11 months (IQR 8-55.5) after surgery. The need for medical treatment for the detrusor overactivity prior to AUS insertion was associated with deterioration of cystometric parameters at 2 years (p = 0.032).
This study reveals an important incidence of deterioration in cystometric parameters after AUS implantation in patients with spinal cord injury. A larger prospective study is needed to confirm these results and to identify risk factors.
人工尿道括约肌(AUS)仍然是治疗神经源性下尿路功能障碍(NLUTD)患者中与括约肌功能不全相关的压力性尿失禁的金标准。本研究旨在评估成年脊髓损伤患者植入AUS后新发神经源性逼尿肌过度活动或膀胱顺应性降低的发生率。
回顾性观察研究,通过分析2003年1月1日至2023年3月31日在神经泌尿外科随访的患者病历进行描述。所遵循的程序符合临床研究和伦理委员会的规定以及世界医学协会的《赫尔辛基宣言》。
纳入39例脊髓损伤患者。术后新发低膀胱顺应性或高压(≥40 cmH₂O)神经源性逼尿肌过度活动的发生率为48.72%,中位发病延迟为术后11个月(IQR 8 - 55.5)。在植入AUS之前需要对逼尿肌过度活动进行药物治疗与2年时膀胱测压参数恶化相关(p = 0.032)。
本研究揭示了脊髓损伤患者植入AUS后膀胱测压参数恶化的重要发生率。需要进行更大规模的前瞻性研究来证实这些结果并确定危险因素。