Wang Peipei, Ren Chao, Wang Liang, Qian Hao, Li Fang, Su Xinhui, Shen Zhujun, Hsu Bailing, Huo Li
Department of Nuclear Medicine, Peking Union Medical College Hospital. Chinese Academy of Medical Science & Peking Union Medical College, Beijing Key Laboratory of Molecular Targeted Diagnosis and Therapy in Nuclear Medicine, Shuaifuyuan, Dongcheng District, Beijing, 100730, China.
Department of Nuclear Medicine, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China.
Eur J Nucl Med Mol Imaging. 2025 Apr;52(5):1864-1877. doi: 10.1007/s00259-024-07004-1. Epub 2024 Dec 17.
This study aimed to evaluate image quality, myocardial perfusion, and diagnostic performance of a novel [F]F-labeled PET tracer, XTR004 PET, myocardial perfusion imaging (MPI) compared with [N]Ammonia (NH) PET MPI.
Forty-seven patients with suspected or known coronary artery disease (CAD) were prospectively enrolled to undergo one-day rest/ATP-stress XTR004 and NH electrocardiograph-gated PET imaging within 2 weeks. Among them, twenty-six patients underwent invasive coronary angiography (ICA), and nineteen were identified with flow-limited CAD (stenosis ≥ 70%). Image quality (excellent/good/average) and certainty of interpretation were evaluated by two independent, blinded readers. Despite a higher liver uptake, XTR004 achieved good to excellent image quality in 83% of cases, comparable to 95.7% of NH(P = 0.091). Additionally, the diagnostic certainty, measured as the percentage of cases with definitely abnormal or normal interpretations, was similar between XTR004 and NH, with results of 87.2% and 89.2%, respectively. The sensitivity and specificity levels of XTR004 and NH MPI were similar (79% vs. 79%, 86% vs. 71%, P = 1.00). Linear regression of rest/stress myocardial perfusion in 17 segments revealed the linear slope close to unity with excellent R value (rest: slope = 0.954-1.074, R = 0.990-0.997; stress: slope = 0.951-1.082, R = 0.971-0.996). XTR004 was tolerated well by all patients. No adverse events were reported.
XTR004 PET MPI demonstrated promising image quality, diagnostic certainty and myocardial perfusion characteristics comparable to NH PET MPI. Future research should concentrate on the quantitative analysis of myocardial blood flow to explore the clinical implications of XTR004 PET MPI.
本研究旨在评估一种新型[F]F标记的PET示踪剂XTR004心肌灌注成像(MPI)的图像质量、心肌灌注及诊断性能,并与[N]氨(NH)PET MPI进行比较。
47例疑似或已知冠心病(CAD)患者被前瞻性纳入研究,在2周内接受为期一天的静息/ATP负荷XTR004和NH心电图门控PET成像。其中,26例患者接受了有创冠状动脉造影(ICA),19例被确诊为血流受限性CAD(狭窄≥70%)。由两名独立的、不知情的阅片者评估图像质量(优秀/良好/一般)和解读的确定性。尽管肝脏摄取较高,但XTR004在83%的病例中获得了良好至优秀的图像质量,与NH的95.7%相当(P = 0.091)。此外,以明确异常或正常解读的病例百分比衡量的诊断确定性,XTR004和NH之间相似,分别为87.2%和89.2%。XTR004和NH MPI的敏感性和特异性水平相似(79%对79%,86%对71%,P = 1.00)。对17个节段的静息/负荷心肌灌注进行线性回归分析,发现线性斜率接近1,R值极佳(静息:斜率 = 0.954 - 1.074,R = 0.990 - 0.997;负荷:斜率 = 0.951 - 1.082,R = 0.971 - 0.996)。所有患者对XTR004耐受性良好。未报告不良事件。
XTR004 PET MPI显示出与NH PET MPI相当的有前景的图像质量、诊断确定性和心肌灌注特征。未来的研究应集中在心肌血流的定量分析上,以探索XTR004 PET MPI的临床意义。