Suppr超能文献

管材和消毒剂对饮用水及生物膜中活性细菌群落的影响

Effect of pipe material and disinfectant on active bacterial communities in drinking water and biofilms.

作者信息

Siponen Sallamaari, Ikonen Jenni, Gomez-Alvarez Vicente, Hokajärvi Anna-Maria, Ruokolainen Matti, Jayaprakash Balamuralikrishna, Kolehmainen Mikko, Miettinen Ilkka T, Pitkänen Tarja, Torvinen Eila

机构信息

University of Eastern Finland, Department of Environmental and Biological Sciences, P.O. Box 1627, FI-70211 Kuopio, Finland.

Finnish Institute for Health and Welfare, Department of Public Health, P.O. Box 95, FI-70701 Kuopio, Finland.

出版信息

J Appl Microbiol. 2025 Jan 6. doi: 10.1093/jambio/lxaf004.

Abstract

AIMS

We investigated the combined effects of pipe materials and disinfection chemicals on bacterial community and its active RNA fraction in water and biofilms in a pilot-scale premise plumbing system.

METHODS AND RESULTS

The changes in bacterial communities were studied within four pipelines using copper and cross-linked polyethylene (PEX) pipe with chlorine or chloramine disinfection. The total and active bacterial communities and the presence of opportunistic pathogens (Legionella spp. and Mycobacterium spp.) were analyzed using 16S rRNA (gene) amplicon sequencing. The dominant classes were Alphaproteobacteria (31%) and Gammaproteobacteria (24%). Class Planctomycetia was increased in active fraction of chlorinated waters and PEX pipe biofilms and decreased in chloraminated waters and copper pipe biofilms. The alpha diversity of the active fractions in biofilms were highest in chloraminated PEX pipe samples (Chao1 mean = 163, p < 0.05, Kruskal-Wallis). Legionella spp. was more abundant and active in waters treated with chlorine than chloramine.

CONCLUSIONS

Disinfectant had a stronger impact than pipe material on the bacterial community composition in water. A combined effect of pipe material and disinfectant was more evident on the composition and activity of the biofilm communities than the individual effect of copper, PEX, chlorine, or chloramine.

摘要

目的

我们在中试规模的室内管道系统中,研究了管材和消毒化学品对水和生物膜中细菌群落及其活性RNA组分的综合影响。

方法与结果

使用铜管和交联聚乙烯(PEX)管,分别用氯或氯胺进行消毒,研究了四条管道内细菌群落的变化。采用16S rRNA(基因)扩增子测序分析了总细菌群落和活性细菌群落,以及机会性病原体(嗜肺军团菌属和分枝杆菌属)的存在情况。优势菌纲为α-变形菌纲(31%)和γ-变形菌纲(24%)。浮霉菌纲在氯化水和PEX管生物膜的活性组分中增加,而在氯胺处理水和铜管生物膜中减少。氯胺处理的PEX管样品中生物膜活性组分的α多样性最高(Chao1平均值 = 163,p < 0.05,Kruskal-Wallis检验)。与氯胺相比,嗜肺军团菌属在氯处理的水中更为丰富且活性更高。

结论

消毒剂对水中细菌群落组成的影响比管材更强。管材和消毒剂的综合作用对生物膜群落的组成和活性的影响比铜、PEX、氯或氯胺的单独作用更为明显。