Berardinelli S P, Hall R
Am Ind Hyg Assoc J. 1985 Feb;46(2):60-4. doi: 10.1080/15298668591394392.
This study explored chemical permeation of latex neoprene gloves by acetone. Twenty-three specific glove sites were monitored to determine the breakthrough time and the challenge liquid concentration at steady-state. In summation, the thinnest parts of the gloves, which are the backs, the palms, and the interstices between the fingers, exhibited the shortest breakthrough times and largest steady-state concentrations. The thickest parts of the gloves, the fingertips, exhibited the longest breakthrough times and least steady-state concentrations. The backs or palms are appropriate specimens to use for chemical permeation testing.
本研究探讨了丙酮对乳胶氯丁橡胶手套的化学渗透作用。监测了23个特定的手套部位,以确定突破时间和稳态下的挑战液浓度。总的来说,手套最薄的部位,即手背、手掌和手指间缝隙,表现出最短的突破时间和最高的稳态浓度。手套最厚的部位,即指尖,表现出最长的突破时间和最低的稳态浓度。手背或手掌是用于化学渗透测试的合适样本。