Suppr超能文献

口内扫描仪记录桩核预备体数字印模的尺寸精度:一项系统评价

Dimensional Accuracy of Intraoral Scanners in Recording Digital Impressions of Post and Core Preparations: A Systematic Review.

作者信息

Alqahtani Saeed M, Almalki Mohammed Salman, Almarzouki Mai, AlResayes Saad Saleh, Hassan Nisreen Nabiel, Mohana Arwa Jaber I, Altoman Majed S, Sayed Mohammed E

机构信息

Department of Prosthetic Dentistry, College of Dentistry, King Khalid University, Abha 62529, Saudi Arabia.

Department of Prosthodontics, Ministry of Health Saudi Arabia, Abha 62461, Saudi Arabia.

出版信息

Diagnostics (Basel). 2024 Dec 23;14(24):2890. doi: 10.3390/diagnostics14242890.

Abstract

BACKGROUND

This study aims to perform a review by selecting, analyzing, and evaluating articles that discuss the accuracy of intraoral scanners (IOSs) in recording post space compared to conventional impression-making techniques.

METHODS

The review question framed using the PITR framework (participant, index test, targeted condition, and reference standard) is as follows: What is the dimensional accuracy (T) of impressions made using intraoral scanners (I) for post space (P) compared to impressions made using conventional techniques and digitalized using extraoral scanners (R)? Four electronic databases were searched using pre-set keywords. The guidelines and strategies recommended by PRISMA formed the basis for planning, executing, and documenting this systematic review. QUADAS-2 was used to critically analyze the quality of all the selected articles.

RESULTS

After excluding ineligible articles, the end synthesis has nine studies ( = 9) for qualitative analysis. All nine evaluated studies were found to be at risk of bias, with high or unclear risk in one or more domains. Three out of nine evaluated studies had unclear concerns regarding the applicability, and the remaining six had low concerns. In all the included studies, the IOSs were reported to have deviations in accuracy compared to the conventional techniques for making digital impressions of post space.

CONCLUSIONS

The accuracy of IOSs was found to be inversely proportional to the length of post space and directly proportional to the diameter of post space. IOSs, when used adequately in short post spaces, can be an alternative to conventional impression-making for making custom posts and cores.

摘要

背景

本研究旨在通过筛选、分析和评估讨论口腔内扫描仪(IOS)与传统印模技术相比在记录桩核空间准确性方面的文章来进行综述。

方法

使用PITR框架(参与者、索引测试、目标条件和参考标准)构建的综述问题如下:与使用传统技术制作并通过口外扫描仪数字化的印模相比,使用口腔内扫描仪(I)制作的桩核空间(P)印模的尺寸准确性(T)如何?使用预设关键词检索了四个电子数据库。PRISMA推荐的指南和策略构成了本系统综述规划、执行和记录的基础。使用QUADAS - 2对所有选定文章的质量进行严格分析。

结果

排除不符合条件的文章后,最终综合有9项研究(n = 9)用于定性分析。发现所有9项评估研究都存在偏倚风险,在一个或多个领域存在高风险或不明确风险。9项评估研究中有3项对适用性的关注不明确,其余6项关注较低。在所有纳入研究中,与传统的桩核空间数字印模技术相比,IOS在准确性方面存在偏差。

结论

发现IOS的准确性与桩核空间长度成反比,与桩核空间直径成正比。当在短桩核空间中充分使用时,IOS可以作为制作定制桩核的传统印模方法的替代方法。