Suppr超能文献

白内障手术中超声乳化和抽吸参数的比较:金属探头与混合探头。

Comparison of Phacoemulsification and Aspiration Parameters in Cataract Surgery: Metal Tip vs. Hybrid Tip.

作者信息

Ichikawa Kazuo, Ichikawa Kei, Tokiwa Seiji, Sato Yuki, Miyazaki Tomoyuki, Tanaka Yoshiki, Yamamoto Naoki

机构信息

Chukyo Eye Clinic, Nagoya, Aichi 456-0032, Japan.

General Aoyama Hospital, Toyokawa, Aichi 441-0103, Japan.

出版信息

Bioengineering (Basel). 2024 Nov 26;11(12):1195. doi: 10.3390/bioengineering11121195.

Abstract

Various tips are available for phacoemulsification in cataract surgery. Evidence-based data can inform ophthalmologists, especially inexperienced ones, on tip selection. We retrospectively evaluated the energy efficiency and other parameters of two ultrasonic phacoemulsification and aspiration tips across different nuclear hardness grades in 342 cataract patients (342 eyes) with nuclear hardness grades II to IV. Surgical procedures, ultrasound settings, and instrumentation were standardized. All surgeries were performed by one experienced doctor. We compared the metal INTREPID Balanced Tip (M-tip) with the INTREPID Hybrid Tip (P-tip), which has a polymer coating. The M-tip required significantly less total ultrasound time and cumulative dissipated energy (CDE) than the P-tip for grades III and IV, while the P-tip had a shorter aspiration time and less estimated fluid aspirated for grade II. No differences in corneal endothelial cell loss were observed. Lens rupture rates were low: 0.47% for the M-tip and 0.78% for the P-tip. Multiple regression analysis showed that CDE increased with nuclear hardness. These findings suggest that the M-tip is efficient for harder lenses, while the P-tip may be advantageous for softer lenses, informing optimal tip selection in cataract surgery. Further research is suggested to elucidate their clinical significance.

摘要

白内障手术中的超声乳化术有多种不同的探头可供选择。循证数据可以为眼科医生,尤其是经验不足的医生在探头选择方面提供参考。我们回顾性评估了342例核硬度为II至IV级的白内障患者(342只眼)在不同核硬度等级下两种超声乳化及抽吸探头的能量效率和其他参数。手术操作、超声设置和器械均实现标准化。所有手术均由一名经验丰富的医生完成。我们将金属INTREPID平衡探头(M探头)与具有聚合物涂层的INTREPID混合探头(P探头)进行了比较。对于III级和IV级患者,M探头所需的总超声时间和累积耗散能量(CDE)明显少于P探头,而对于II级患者,P探头的抽吸时间更短,估计吸出的液体量更少。未观察到角膜内皮细胞损失的差异。晶状体破裂率较低:M探头为0.47%,P探头为0.78%。多元回归分析表明,CDE随核硬度增加而增加。这些发现表明,M探头对较硬的晶状体更有效,而P探头对较软的晶状体可能更具优势,这为白内障手术中最佳探头的选择提供了依据。建议进一步开展研究以阐明它们的临床意义。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/2f9d/11727584/8a2d007ae979/bioengineering-11-01195-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验