Abstract

During closed-circuit anesthesia, the patient's inspired gas may become progressively contaminated by nonanesthetic gases. We studied the concentrations of methane, acetone, and nitrogen as nonanesthetic gas contaminants in the circuit gas of 16 cases during closed-circuit anesthesia. After a "short" period of denitrogenation (6-8 min), average nitrogen concentration in the closed circuit increased from 6.4 to 16.2%, methane from 4.3 to 22.4 ppm, and acetone from 0.3 to 2.2 ppm. After "long" denitrogenation (33 min), average nitrogen concentration in the closed circuit increased from 1.0 to 5.1%, methane from 3.7 to 17.9 ppm, and acetone from 1.3 to 5.9 ppm. It is concluded that gases stored in tissues or produced within the body can appear in the patient's expired gas during closed-circuit anesthesia. Intermittent flushing of the circuit with high flow gases is suggested to remove these contaminants.

摘要

在紧闭式麻醉期间,患者的吸入气体可能会逐渐被非麻醉气体污染。我们研究了16例紧闭式麻醉患者回路气体中作为非麻醉气体污染物的甲烷、丙酮和氮气的浓度。经过“短时间”去氮(6 - 8分钟)后,紧闭回路中的平均氮气浓度从6.4%升至16.2%,甲烷从4.3 ppm升至22.4 ppm,丙酮从0.3 ppm升至2.2 ppm。经过“长时间”去氮(33分钟)后,紧闭回路中的平均氮气浓度从1.0%升至5.1%,甲烷从3.7 ppm升至17.9 ppm,丙酮从1.3 ppm升至5.9 ppm。得出的结论是,储存在组织中或体内产生的气体在紧闭式麻醉期间可能会出现在患者呼出的气体中。建议用高流量气体间歇性冲洗回路以去除这些污染物。