Suppr超能文献

手术分娩时合适真空吸引器的选择:一项生物力学研究。

Selection of the apposite vacuum extractor during operative delivery: A biomechanical study.

作者信息

Hsieh Ping-Lin, Wang Peng-Hui, Ke Jyun-Cheng, Chiang Kai-Jo, Lin Chi-Kang, Chang Fung-Wei, Su Kuo-Min, Su Kuo-Chih

机构信息

Department of Obstetrics and Gynecology, Tri-Service General Hospital, National Defense Medical Center, Taipei, Taiwan, ROC.

Department of Obstetrics and Gynecology, School of Medicine, National Defense Medical Center, Taipei, Taiwan, ROC.

出版信息

J Chin Med Assoc. 2025 Mar 1;88(3):253-260. doi: 10.1097/JCMA.0000000000001204. Epub 2024 Dec 30.

Abstract

BACKGROUND

Operative delivery is a technique used during vaginal or cesarean birth to facilitate the patient's labor course through the assistance of a vacuum extractor. This method is increasingly used compared with forceps. This study aimed to investigate the forced effects of vacuum extractors comprising vacuum cups with different thicknesses on the fetal head and the vacuum extractor during vacuum-assisted delivery and to determine the optimal thickness for reducing the failure rate and minimizing neonatal and maternal morbidity.

METHODS

A biomechanical model was developed to examine the impact of vacuum cups with varying thicknesses. This simulation three-dimensional (3D) geometry model was used to evaluate hemispherical-shaped vacuum extractors made of silicone rubber having a similar cup diameter of 70 mm with varying thicknesses (1-5 mm), which were applied to the three models (flat surfaces, hemispherical balls, and fetal head). Under one boundary condition and two different loading conditions, finite element analysis was utilized to simulate the force of vacuum extractors on the fetal head during the process of operative delivery. The main observation indicators were the reaction forces of the constructed model, and von Mises stress on both the vacuum extractors and fetal head.

RESULTS

For the reaction forces on each axis, we found that the sum of the reaction force values on each axis was increased as the thickness of the vacuum extractor was increased, regardless of the surface type. In addition, the reaction force of the fixed-support end was increased with the increased thickness of the vacuum extractor. The von Mises stress distributions of vacuum extractors comprising vacuum cups with different thicknesses, revealed that the thinner the cup, the greater the von Mises stress exerted on the extractor itself regardless of the surface type. The distribution of von Mises stress on the skull structure of the fetal head showed that the thinner the cup, the greater the von Mises stress exerted on the skull structure regardless of the surface type.

CONCLUSION

A thinner vacuum extractor cup may result in greater injury to the fetus; hence, a thicker vacuum extractor cup is preferably utilized during vacuum-assisted operative delivery. Using a thicker vacuum extractor should yield a higher successful delivery rate and reduce fetal injury.

摘要

背景

手术分娩是在阴道分娩或剖宫产过程中使用的一种技术,通过真空吸引器的辅助来促进产妇的产程。与产钳相比,这种方法的使用越来越广泛。本研究旨在探讨不同厚度的真空杯组成的真空吸引器在真空辅助分娩过程中对胎儿头部和真空吸引器的受力影响,并确定能降低失败率以及使新生儿和产妇发病率最小化的最佳厚度。

方法

建立了一个生物力学模型来研究不同厚度真空杯的影响。这个模拟三维(3D)几何模型用于评估由硅橡胶制成的半球形真空吸引器,其杯直径相似为70毫米,厚度不同(1 - 5毫米),将其应用于三个模型(平面、半球形球和胎儿头部)。在一种边界条件和两种不同加载条件下,利用有限元分析来模拟手术分娩过程中真空吸引器对胎儿头部的作用力。主要观察指标是构建模型的反作用力以及真空吸引器和胎儿头部上的冯·米塞斯应力。

结果

对于每个轴向上的反作用力,我们发现无论表面类型如何,随着真空吸引器厚度的增加,每个轴向上的反作用力值总和都会增加。此外,固定支撑端的反作用力随着真空吸引器厚度的增加而增加。由不同厚度真空杯组成的真空吸引器的冯·米塞斯应力分布表明,无论表面类型如何,杯越薄,施加在吸引器自身上的冯·米塞斯应力就越大。胎儿头部颅骨结构上的冯·米塞斯应力分布表明,无论表面类型如何,杯越薄,施加在颅骨结构上的冯·米塞斯应力就越大。

结论

较薄的真空吸引器杯可能会对胎儿造成更大的损伤;因此,在真空辅助手术分娩期间最好使用较厚的真空吸引器杯。使用较厚的真空吸引器应该能获得更高的分娩成功率并减少胎儿损伤。