INTRODUCTION

In this article, we report a unique case of head-stem dissociation in a metal-on-metal total hip replacement which utilized an Exeter stem. Although metallosis and pseudotumor formation are well recognized complications of metal-on-metal hip replacements, head-stem dissociations are rare with few being reported in literature. To the best of our knowledge, this case report is the first to report this occurrence in an Exeter stem.

CASE REPORT

A 76-year-old male presented to the emergency department with pain and discomfort in his left hip triggered by a twisting movement while getting into bed. The patient described a "pop" in his hip upon turning and reported mild ongoing discomfort in his left hip for the past 4 weeks before this acute presentation. X-rays and Metal artifact reduction sequence magnetic resonance image (MARS) revealed head-stem dissociation along with pseudotumor formation. The patient successfully underwent a two stage revision with no perioperative complications.

CONCLUSION

This case report, to the best of our knowledge, is the first to report catastrophic failure of a metal-on-metal hip caused by trunnionosis and subsequent head-stem dissociation. We report successful management of this unique case and hope to highlight the complexities and challenges associated with metal-on-metal THR. This case report is aimed at raising clinical awareness of this rare complication which requires expert management for a successful outcome.

摘要

引言

在本文中,我们报告了一例使用埃克塞特柄的金属对金属全髋关节置换术中罕见的头柄分离病例。尽管金属沉着病和假肿瘤形成是金属对金属髋关节置换术公认的并发症,但头柄分离很少见,文献报道较少。据我们所知,本病例报告是首次报道埃克塞特柄出现这种情况。

病例报告

一名76岁男性因上床时扭转动作引发左髋疼痛和不适就诊于急诊科。患者称转身时髋部有“啪”的一声,并报告在此次急性发作前的过去4周里左髋一直有轻度不适。X线和金属伪影减少序列磁共振成像(MARS)显示头柄分离以及假肿瘤形成。患者成功接受了两阶段翻修手术,无围手术期并发症。

结论

据我们所知,本病例报告是首次报道由耳轴病及随后的头柄分离导致的金属对金属髋关节灾难性失败。我们报告了对这一独特病例的成功处理,并希望强调与金属对金属全髋关节置换相关的复杂性和挑战。本病例报告旨在提高对这种罕见并发症的临床认识,其需要专家处理才能获得成功结果。