BACKGROUND AND PURPOSE

Measuring patient satisfaction after total hip (THA) and total knee arthroplasty (TKA) is important. We aimed to cross-culturally adapt and examine the psychometric properties of the self-reported Goodman Satisfaction Score (GSS) in a sample of Norwegian patients following primary THA and TKA.

METHODS

The GSS was translated and adapted into Norwegian (GSS-NO) following standard guidelines. 800 patients from the Norwegian Arthroplasty Register who had undergone surgery 6-11 months prior were invited to complete GSS-NO and questions on sociodemographic factors, pain, and function in a cross-sectional study. We examined validity in relation to internal structure, response processes, and precision using Rasch analysis, relationships between the GSS-NO and pain and function using Pearson's correlation coefficients, and test-retest reliability using linear weighted kappa statistics.

RESULTS

The GSS-NO was adapted with few challenges. 404 patients (49% THA, 51% TKA) returned complete answers. The GSS-NO met all criteria regarding the rating scale functioning. Local independence among items and unidimensionality was supported and there was acceptable goodness-of-fit. The internal consistency was 0.94. We found no systematic differential item functioning by age, sex, work status, education, cohabitation status, or hip or knee surgery. The correlation coefficients between GSS-NO and pain and function outcomes were 0.79 (95% confidence interval [CI] 0.76-0.82) and 0.79 (CI 0.76-0.82), respectively. Test-retest reliability with weighted kappa ranged from 0.43-0.55 for THA and 0.54-0.81 for TKA.

CONCLUSION

The cross-cultural adaptation of GSS-NO proved to be a valid and reliable measure for use in Norwegian-speaking patients following primary THA and TKA.

摘要

背景与目的

测量全髋关节置换术(THA)和全膝关节置换术(TKA)后的患者满意度很重要。我们旨在对自我报告的古德曼满意度评分(GSS)进行跨文化调适,并在挪威初次行THA和TKA的患者样本中检验其心理测量特性。

方法

按照标准指南将GSS翻译成挪威语(GSS-NO)。在一项横断面研究中,邀请挪威关节置换登记处800名在6-11个月前接受手术的患者完成GSS-NO以及关于社会人口学因素、疼痛和功能的问题。我们使用拉施分析检验与内部结构、反应过程和精确度相关的效度,使用皮尔逊相关系数检验GSS-NO与疼痛和功能之间的关系,并使用线性加权kappa统计量检验重测信度。

结果

GSS-NO的调适几乎没有遇到挑战。404名患者(49%为THA,51%为TKA)返回了完整答案。GSS-NO符合关于量表功能的所有标准。项目间局部独立性和单维性得到支持,且拟合优度可接受。内部一致性为0.94。我们未发现年龄、性别、工作状态、教育程度、同居状态或髋关节或膝关节手术导致的系统性差异项目功能。GSS-NO与疼痛和功能结果的相关系数分别为0.79(95%置信区间[CI]0.76-0.82)和0.79(CI 0.76-0.82)。THA的重测信度加权kappa范围为0.43-0.55,TKA为0.54-0.81。

结论

事实证明,GSS-NO的跨文化调适是一种有效且可靠的测量方法,可用于挪威语患者的初次THA和TKA术后。