Ten uncemented total hip replacements were performed in 1975 using an implant in which the cobalt-chrome femoral stem was coated to give a porous surface. In all but one case a high-density polyethylene head was used. The radiological changes in the upper femoral shafts were assessed between three and nine years later. Seven showed extensive stress-relieving changes, loss of calcar, stress fractures at the root of the lesser trochanter with subsequent detachment, and osteoporosis followed by avulsion of the greater trochanter. In these seven patients the lower part of the stem appeared to be soundly embedded, although in only one was there evidence of bony incorporation. It is suggested that if the fixation of a fully coated implant of this sort remains sound, gross atrophy of the upper femoral shaft develops after five years. This atrophy, associated with an implant which can be removed only at the expense of further bone destruction, presents substantial problems if revision is needed.

摘要

1975年采用一种钴铬合金股骨干涂层以形成多孔表面的植入物进行了10例非骨水泥型全髋关节置换术。除1例以外,其余均使用高密度聚乙烯股骨头。在三至九年后评估股骨干上段的放射学变化。7例显示出广泛的应力缓解改变、股骨距丧失、小转子根部应力性骨折并随后分离,以及骨质疏松,继而大转子撕脱。在这7例患者中,假体柄下部似乎牢固植入,尽管只有1例有骨长入的证据。提示如果这种全涂层假体的固定保持良好,股骨干上段在五年后会出现明显萎缩。这种萎缩与一种只有以进一步破坏骨质为代价才能取出的植入物相关,如果需要翻修则会带来重大问题。